Ontology highlight
ABSTRACT: Background
Severe acute respiratory syndrome-related coronavirus 2 (SARS-CoV-2) surrogate neutralization assays that obviate the need for viral culture offer substantial advantages regarding throughput and cost. The cPass SARS-CoV-2 Neutralization Antibody Detection Kit (GenScript) is the first such commercially available assay that detects antibodies that block receptor-binding domain (RBD)/angiotensin-converting enzyme (ACE)-2 interaction. We aimed to evaluate cPass to inform its use and assess its added value compared with anti-RBD enzyme-linked immunosorbent assays (ELISAs).Methods
Serum reference panels comprising 205 specimens were used to compare cPass to plaque-reduction neutralization test (PRNT) and a pseudotyped lentiviral neutralization (PLV) assay for detection of neutralizing antibodies. We assessed the correlation of cPass with an ELISA detecting anti-RBD immunoglobulin (Ig)G, IgM, and IgA antibodies at a single timepoint and across intervals from onset of symptoms of SARS-CoV-2 infection.Results
Compared with PRNT-50, cPass sensitivity ranged from 77% to 100% and specificity was 95% to 100%. Sensitivity was also high compared with the pseudotyped lentiviral neutralization assay (93%; 95% confidence interval [CI], 85-97), but specificity was lower (58%; 95% CI, 48-67). Highest agreement between cPass and ELISA was for anti-RBD IgG (r = 0.823). Against the pseudotyped lentiviral neutralization assay, anti-RBD IgG sensitivity (99%; 95% CI, 94-100) was very similar to that of cPass, but overall specificity was lower (37%; 95% CI, 28-47). Against PRNT-50, results of cPass and anti-RBD IgG were nearly identical.Conclusions
The added value of cPass compared with an IgG anti-RBD ELISA was modest.
SUBMITTER: Papenburg J
PROVIDER: S-EPMC8135688 | biostudies-literature |
REPOSITORIES: biostudies-literature