Project description:BackgroundLeft-ventricular systolic dyssynchrony (LVSD) has been an important prognostic factor in the patients with dilated cardiomyopathy (DCM). However, the association between the LV diastolic dyssynchrony (LVDD) and clinical outcome is not well established. This study aims to evaluate the prognostic values of both systolic and diastolic dyssynchrony in patients with DCM.MethodsFifty-two patients with DCM were enrolled and divided into two groups according to cardiac deaths from the follow-up data. The phase-analysis technique was applied on resting gated short-axis SPECT MPI images to measure LV systolic and diastolic dyssynchrony, including phase standard deviation (PSD), phase histogram bandwidth (PBW), and phase entropy (PE). Variables with P < 0.10 in the univariate analysis were included in the multivariate cox analysis.ResultsDuring the follow-up period (2.9 ± 1.7 years), 18 (34.6%) cardiac deaths were observed. Compared with survivors, patients with cardiac death had lower LVEF (P = 0.011), and more severe LV systolic and diastolic dyssynchrony. The univariate cox regression analysis showed that hypertension, NT-proBNP, LVEF, systolic PSD, systolic PE, and diastolic PBW were statistically significantly associated with cardiac death. The multivariate cox regression analysis showed that systolic PE and diastolic PE were independent predictive factors for cardiac death. Furthermore, the receiver operating characteristic (ROC) analysis, when applied into the combination of systolic PE and diastolic PE for predicting cardiac death, had an area under curve (AUC) of 0.766, a sensitivity of 0.765, and a specificity of 0.722.ConclusionsBoth the LVSD and LVDD parameters from SPECT MPI have important prognostic values for DCM patients. Both systolic PE and diastolic PE are independent prognostic factors for cardiac death.
Project description:BackgroundThe purpose of this study was to evaluate the predictive value of left ventricular (LV) shape parameters measured by gated SPECT myocardial perfusion imaging (MPI) in super-responders enrolled in the VISION-CRT trial.MethodsOne hundred and ninety-nine patients who met standard criteria for CRT from multiple centers were enrolled in this study. End-systolic eccentricity (ESE) and end-diastolic eccentricity (EDE) were measures of LV shape. Super-responders were the patients who had a relative increase in left ventricular ejection fraction (LVEF) ≥ 15%.ResultsComplete data were obtained in 165 patients, and 43.6% of them were classified as super-responders. ESE was an independent predictor of CRT super-responders in univariate (OR 12.59, 95% CI 1.56-101.35, P = .017) and multivariate analysis (OR 35.71, 95% CI 1.66-766.03, P = .006). ESE had an incremental value over significant clinical and SPECT imaging variables, including angiotensin-converting enzyme inhibitors or angiotensin II receptor blocker, coronary artery disease, myocardial infarction, LVEF, end-diastolic volume index, and scar burden (AUC 0.82 vs. 0.80, sensitivity 0.68 vs. 0.65, specificity 0.82 vs. 0.78).ConclusionsLV shape parameters derived from gated SPECT MPI have the promise to improve the prediction of the super-response to CRT. Moreover, ESE provides incremental value over existing clinical and nuclear imaging variables.
Project description:BackgroundPlacing the left ventricular (LV) lead in a viable segment with the latest mechanical activation (vSOLA) may be associated with optimal cardiac resynchronization therapy (CRT) response. We assessed the role of gated SPECT myocardial perfusion imaging (gSPECT MPI) in predicting clinical outcomes at 6 months in patients submitted to CRT.MethodsTen centers from 8 countries enrolled 195 consecutive patients. All underwent gSPECT MPI before and 6 months after CRT. The procedure was performed as per current guidelines, the operators being unaware of gSPECT MPI results. Regional LV dyssynchrony (Phase SD) and vSOLA were automatically determined using a 17 segment model. The lead was considered on-target if placed in vSOLA. The primary outcome was improvement in ≥1 of the following: ≥1 NYHA class, left ventricular ejection fraction (LVEF) by ≥5%, reduction in end-systolic volume by ≥15%, and ≥5 points in Minnesota Living With Heart Failure Questionnaire (MLHFQ).ResultsSixteen patients died before the follow-up gSPECT MPI. The primary outcome occurred in 152 out of 179 (84.9%) cases. Mean change in LV phase standard deviation (PSD) at 6 months was 10.5°. Baseline dyssynchrony was not associated with the primary outcome. However, change in LV PSD from baseline was associated with the primary outcome (OR 1.04, 95% CI 1.01-1.07, P = .007). Change in LV PSD had an AUC of 0.78 (0.66-0.90) for the primary outcome. Improvement in LV PSD of 4° resulted in the highest positive likelihood ratio of 7.4 for a favorable outcome. In 23% of the patients, the CRT lead was placed in the vSOLA, and in 42% in either this segment or in a segment within 10° of it. On-target lead placement was not significantly associated with the primary outcome (OR 1.53, 95% CI 0.71-3.28).ConclusionLV dyssynchrony improvement by gSPECT MPI, but not on-target lead placement, predicts clinical outcomes in patients undergoing CRT.
Project description:Due to partly conflicting studies, further research is warranted with the QGS software package, with regard to the performance of gated FDG PET phase analysis as compared to gated MPS as well as the establishment of possible cut-off values for FDG PET to define dyssynchrony. Gated MPS and gated FDG PET datasets of 93 patients were analyzed with the QGS software. BW, Phase SD, and Entropy were calculated and compared between the methods. The performance of gated PET to identify dyssynchrony was measured against SPECT as reference standard. ROC analysis was performed to identify the best discriminator of dyssynchrony and to define cut-off values. BW and Phase SD differed significantly between the SPECT and PET. There was no significant difference in Entropy with a high linear correlation between methods. There was only moderate agreement between SPECT and PET to identify dyssynchrony. Entropy was the best single PET parameter to predict dyssynchrony with a cut-off point at 62%. Gated MPS and gated FDG PET can assess LVMD. The methods cannot be used interchangeably. Establishing reference ranges and cut-off values is difficult due to the lack of an external gold standard. Further prospective research is necessary.
Project description:BackgroundCardiac resynchronization therapy (CRT) patients with different pathophysiology may influence mechanical dyssynchrony and get different ventricular resynchronization and clinical outcomes.MethodsNinety-two dilated cardiomyopathy (DCM) and fifty ischemic cardiomyopathy (ICM) patients with gated single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) were included in this retrospective study. Patients were classified based on the concordance between the left ventricular (LV) lead and the latest contraction or relaxation position. If the LV lead was located on or adjacent to both the latest contraction and relaxation position, the patient was categorized into the both match group; if the LV lead was located on or adjacent to the latest contraction or relaxation position, the patient was classified into the one match group; if the LV lead was located on or adjacent to neither the latest contraction nor relaxation position, the patient was categorized to the neither group. CRT response was defined as [Formula: see text] improvement of LV ejection fraction at the 6-month follow-up. Variables with P < .05 in the univariate analysis were included in the stepwise multivariate model.ResultsDuring the follow-up period, 58.7% (54 of 92) for DCM patients and 54% (27 of 50) for ICM patients were CRT responders. The univariate analysis and stepwise multivariate analysis showed that QRS duration, systolic phase bandwidth (PBW), diastolic PBW, diastolic phase histogram standard deviation (PSD), and left ventricular mechanical dyssynchrony (LVMD) concordance were independent predictors of CRT response in DCM patients; diabetes mellitus and left ventricular end-systolic volume were significantly associated with CRT response in ICM patients. The intra-group comparison revealed that the CRT response rate was significantly different in the both match group of DCM (N = 18, 94%) and ICM (N = 24, 62%) patients (P = .016). However, there was no significant difference between DCM and ICM in the one match and neither group. For the inter-group comparison, Kruskal-Wallis H-test revealed that CRT response was significantly different in all the groups of DCM patients (P < .001), but not in ICM patients (P = .383).ConclusionsCompared with ICM patients, systolic PBW, diastolic PBW and PSD have better predictive and prognostic values for the CRT response in DCM patients. Placing the LV lead in or adjacent to the latest contraction and relaxation position can improve the clinical outcomes of DCM patients, but it does not apply to ICM patients.
Project description:BackgroundStudies have shown that the conventional parameters characterizing left ventricular mechanical dyssynchrony (LVMD) measured on gated SPECT myocardial perfusion imaging (MPI) have their own statistical limitations in predicting cardiac resynchronization therapy (CRT) response. The purpose of this study is to discover new predictors from the polarmaps of LVMD by deep learning to help select heart failure patients with a high likelihood of response to CRT.MethodsOne hundred and fifty-seven patients who underwent rest gated SPECT MPI were enrolled in this study. CRT response was defined as an increase in left ventricular ejection fraction (LVEF) > 5% at 6 [Formula: see text] 1 month follow up. The autoencoder (AE) technique, an unsupervised deep learning method, was applied to the polarmaps of LVMD to extract new predictors characterizing LVMD. Pearson correlation analysis was used to explain the relationships between new predictors and existing clinical parameters. Patients from the IAEA VISION-CRT trial were used for an external validation. Heatmaps were used to interpret the AE-extracted feature.ResultsComplete data were obtained in 130 patients, and 68.5% of them were classified as CRT responders. After variable selection by feature importance ranking and correlation analysis, one AE-extracted LVMD predictor was included in the statistical analysis. This new AE-extracted LVMD predictor showed statistical significance in the univariate (OR 2.00, P = .026) and multivariate (OR 1.11, P = .021) analyses, respectively. Moreover, the new AE-extracted LVMD predictor not only had incremental value over PBW and significant clinical variables, including QRS duration and left ventricular end-systolic volume (AUC 0.74 vs 0.72, LH 7.33, P = .007), but also showed encouraging predictive value in the 165 patients from the IAEA VISION-CRT trial (P < .1). The heatmaps for calculation of the AE-extracted predictor showed higher weights on the anterior, lateral, and inferior myocardial walls, which are recommended as LV pacing sites in clinical practice.ConclusionsAE techniques have significant value in the discovery of new clinical predictors. The new AE-extracted LVMD predictor extracted from the baseline gated SPECT MPI has the potential to improve the prediction of CRT response.
Project description:PURPOSE: To compare left ventricular (LV) dyssynchrony assessment by phase analysis from gated myocardial perfusion SPECT (GMPS) with LV dyssynchrony assessment by tri-plane tissue Doppler imaging (TDI). Baseline LV dyssynchrony assessed with standard deviation (SD) of time-to-peak systolic velocity of 12 LV segments (Ts-SD) with TDI has proven to be a powerful predictor of response to CRT. Information on LV dyssynchrony can also be provided by GMPS with phase analysis of regional LV maximal count changes throughout the cardiac cycle. METHODS: Forty heart failure patients, referred for evaluation of potential eligibility for CRT, underwent both 3D echocardiography, with tri-plane TDI, and resting GMPS. From tri-plane TDI, Ts-SD was used as a validated parameter of LV dyssynchrony and compared with different indices (histogram bandwidth, phase SD, histogram skewness and kurtosis) derived from phase analysis of GMPS. RESULTS: Histogram bandwidth and phase SD showed good correlation with Ts-SD (r=0.77 and r=0.74, p<0.0001, respectively). Patients with substantial LV dyssynchrony assessed with tri-plane TDI (Ts-SD >or=33 ms) had also significantly higher values of histogram bandwidth and phase SD. CONCLUSIONS: The results of this study support the use of phase analysis by GMPS to evaluate LV dyssynchrony. Histogram bandwidth and phase SD showed the best correlation with Ts-SD assessed with tri-plane TDI and appeared the most optimal variables for assessment of LV dyssynchrony with GMPS.
Project description:AimsComputed tomographic attenuation correction (CTAC) scans for single photon emission computed tomography myocardial perfusion imaging (SPECT-MPI) may reveal coronary artery calcification. The independent prognostic value of a visually estimated coronary artery calcium score (VECACS) from these low-dose, non-gated scans is not established.Methods & resultsVECACS was evaluated in 4,720 patients undergoing SPECT-MPI with CTAC using a 4-point scale. Major adverse cardiac events (MACE) were defined as all-cause mortality, acute coronary syndrome, or revascularization > 90 days after SPECT-MPI. Independent associations with MACE were determined with multivariable Cox proportional hazards analyses adjusted for age, sex, past medical history, perfusion findings, and left ventricular ejection fraction. During a median follow up of 2.9 years (interquartile range 1.8 - 4.2), 494 (10.5%) patients experienced MACE. Compared to absent VECACS, patients with increased VECACS were more likely to experience MACE (all log-rank p < 0.001), and findings were similar when stratified by normal or abnormal perfusion. Multivariable analysis showed an increased MACE risk associated with VECACS categories of equivocal (adjusted hazard ratio [HR] 2.54, 95% CI 1.45-4.45, p = 0.001), present (adjusted HR 2.44, 95% CI 1.74-3.42, p < 0.001) and extensive (adjusted HR 3.47, 95% CI 2.41-5.00, p < 0.001) compared to absent. Addition of VECACS to the multivariable model improved risk classification (continuous net reclassification index 0.207, 95% CI 0.131 - 0.310).ConclusionVECACS was an independent predictor of MACE in this large SPECT-MPI patient cohort. VECACS from CTAC can be used to improve risk stratification with SPECT-MPI without additional radiation.
Project description:(1) Objective: The objective of this study was to assess the prognostic value of stress-gated blood pool SPECT (GBPS) estimates in patients with ischemic cardiomyopathy (ICM) in the early postoperative period. (2) Methods: A total of 57 patients (age 59.7 ± 6.6, 47 men) with ICM and LV ejection fraction (30 [27.5; 35]%) were enrolled in the study. Before surgical treatment, all patients underwent GBPS (rest-stress, dobutamine doses of 5/10/15 µg/kg/min). Stress-induced changes in left ventricular (LV) ejection fraction, peak ejection rate, volumes, and mechanical dyssynchrony (phase histogram standard deviation, phase entropy (PE), and phase histogram bandwidth) were estimated. Two-dimensional transthoracic echocardiography was performed baseline. Serum levels of NT-proBNP were analyzed with enzyme-linked immunoassay. (3) Results: After surgical treatment, patients were divided into two groups, one, with death, the need for an intra-aortic balloon pump (IABP) or/and inotropic support with a stay in the intensive care unit for more than two days and two, without complications in the early postoperative period (EPOP). Complicated EPOP (CEPOP) was observed in 17 (30%) patients (death-2, IABP-4, extra inotropic support in intensive care unit-11), and 40 patients had no complications (NCEPOP). GBPS showed differences in LV EDV (mL) (321 [268; 358] vs. 268 [242; 313], p = 0.02), LV ESV (mL) (242 [201; 282] vs. 196 [170; 230], p = 0.005), and stress-induced changes in PE (1 (-2; 3) vs. -2 (-4; 0), p = 0.02). Aortic cross-clamp time and stress-induced changes in PE between rest and dobutamine dose of 10 µg/kg/min were the only independent predictors of CEPOP. An increase in LV entropy ≥ 1 on the dobutamine dose of 10µg/kg/min in comparison to rest investigation showed AUC = 0.853 (sensitivity = 62%, specificity = 90%, PPV = 71%; NPV = 85%; p < 0.0001). Conclusion: Stress-induced changes in PE obtained during low-dose dobutamine GBPS are associated with a complicated course of the early postoperative period after surgical treatment for ICM.
Project description:BACKGROUND:Consistency of results between different readers is an important issue in medical imaging, as it affects portability of results between institutions and may affect patient care. The International Atomic Energy Agency (IAEA) in pursuing its mission of fostering peaceful applications of nuclear technologies has supported several training activities in the field of nuclear cardiology (NC) and SPECT myocardial perfusion imaging (MPI) in particular. The aim of this study was to verify the outcome of those activities through an international clinical audit on MPI where participants were requested to report on studies distributed from a core lab. METHODS:The study was run in two phases: in phase 1, SPECT MPI studies were distributed as raw data and full processing was requested as per local practice. In phase 2, images from studies pre-processed at the core lab were distributed. Data to be reported included summed stress score (SSS); summed rest score (SRS); summed difference score (SDS); left ventricular (LV) ejection fraction (EF) and end- diastolic volume (EDV). Qualitative appraisals included the assessment of perfusion and presence of ischemia, scar or mixed patterns, presence of transient ischemic dilation (TID), and risk for cardiac events (CE). Twenty-four previous trainees from low- and middle-income countries participated (core participants group) and their results were assessed for inter-observer variability in each of the two phases, and for changes between phases. The same evaluations were performed for a group of eleven international experts (experts group). Results were also compared between the groups. RESULTS:Expert readers showed an excellent level of agreement for all parameters in both phase 1 and 2. For core participants, the concordance of all parameters in phase 1 was rated as good to excellent. Two parameters which were re-evaluated in phase 2, namely SSS and SRS, showed an increased level of concordance, up to excellent in both cases. Reporting of categorical variables by expert readers remained almost unchanged between the two phases, while core participants showed an increase in phase 2. Finally, pooled LVEF values did not show a significant difference between core participants and experts. However, significant differences were found between LVEF values obtained using different software packages for cardiac analysis. CONCLUSIONS:In this study, inter-observer agreement was moderate-to-good for core group readers and good-to-excellent for expert readers. The quality of reporting is affected by the quality of processing. These results confirm the important role of the IAEA training activities in improving imaging in low- and middle-income countries.