ABSTRACT: Purpose
To evaluate long-term outcomes and complications of sutured scleral-fixated foldable intraocular lens (IOL) implantation.Design
Retrospective study.Methods
Patients who underwent sutured scleral-fixated foldable IOL implantation using 10-0 polypropylene suture were followed up for at least 5 years at one Chinese tertiary hospital and two primary hospitals.Results
52 eyes among 48 patients (35 male and 13 female) were evaluated. The mean age (years) was 50.27 ± 20.08 (range: 6 to 81). The mean postoperative follow-up time (months) was 79.70 ± 18.84 (range: 60 to 121). The mean best-corrected visual acuity (BCVA) improved from 0.83 ± 0.69 logarithm of the minimum angle of resolution (logMAR) at baseline to 0.50 ± 0.45 logMAR at the last follow-up visit
SUBMITTER: Yu T
PROVIDER: S-EPMC8310451 | biostudies-literature | 2021
REPOSITORIES: biostudies-literature