Unknown

Dataset Information

0

Membrane Fouling Controlled by Adjustment of Biological Treatment Parameters in Step-Aerating MBR.


ABSTRACT: A promising solution for membrane fouling reduction in membrane bioreactors (MBRs) could be the adjustment of operating parameters of the MBR, such as hydraulic retention time (HRT), food/microorganisms (F/M) loading and dissolved oxygen (DO) concentration, aiming to modify the sludge morphology to the direction of improvement of the membrane filtration. In this work, these parameters were investigated in a step-aerating pilot MBR that treated municipal wastewater, in order to control the filamentous population. When F/M loading in the first aeration tank (AT1) was ≤0.65 ± 0.2 g COD/g MLSS/d at 20 ± 3 °C, DO = 2.5 ± 0.1 mg/L and HRT = 1.6 h, the filamentous bacteria were controlled effectively at a moderate filament index of 1.5-3. The moderate population of filamentous bacteria improved the membrane performance, leading to low transmembrane pressure (TMP) at values ≤ 2 kPa for a great period, while at the control MBR the TMP gradually increased reaching 14 kPa. Soluble microbial products (SMP), were also maintained at low concentrations, contributing additionally to the reduction of ΤΜP. Finally, the step-aerating MBR process and the selected imposed operating conditions of HRT, F/M and DO improved the MBR performance in terms of fouling control, facilitating its future wider application.

SUBMITTER: Banti DC 

PROVIDER: S-EPMC8399131 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC6316618 | biostudies-literature
| S-EPMC8706986 | biostudies-literature
| S-EPMC9065567 | biostudies-literature
| PRJNA976645 | ENA
| S-EPMC4180805 | biostudies-literature
| PRJNA844170 | ENA
| S-EPMC9866803 | biostudies-literature
| S-EPMC6065318 | biostudies-literature
| S-EPMC8467550 | biostudies-literature
| S-EPMC9143739 | biostudies-literature