Project description:BackgroundThree-dimensional printing (3DP) is increasingly used to individualise surgery and may be an effective tool for representing patient anatomy. Current literature on patient-specific anatomical models (biomodels) for minimally invasive spinal surgery is a limited number of case series and cohort studies. However, studies investigating 3DP in other specialties have reported multiple benefits.MethodsThis prospective study considered a series of patients (n=33) undergoing elective endoscopic spinal surgery, including combinations of microdiscectomy (n=27), foraminotomy (n=7), and laminectomy (n=3). These surgeries were conducted at vertebral levels ranging from L2/3 to L5/S1. The surgeon then recorded the impact on preoperational planning, intraoperative decision-making and accelerating the learning curve with a qualitative questionnaire.ResultsThere were benefits to planning in 54.5% of cases (n=18), improved intraoperative decision-making in 60.6% of cases (n=20). These benefits were reported more frequently earlier in the cases, with improvements to learning reported in 60% of the first five cases and not in subsequent cases. The surgeon commented that the biomodels were more useful on.ConclusionsThe rates of preoperative and intraoperative benefits are consistent with existing studies, and the early benefit to the learning curve may be suitable for applications to surgical training. Additional research is required to determine the practicality of biomodels and their impact on patient outcomes for endoscopic spinal surgery.
Project description:Mallet finger deformity is a common and debilitating injury of the fingertip, accounting for 10% of all tendon and ligament injuries. It involves a disruption of the terminal extensor mechanism of the distal phalanx. Patients can experience significant pain and swelling of the fingertip and have significant morbidity without treatment. Nonoperative treatment using joint immobilization with splints is the mainstay of management. Traditionally, prefabricated and thermoplastic splints have been utilized; however, issues with comfort and skin complications such as maceration can lead to patient noncompliance and eventually, poor outcomes. To address this, we demonstrate our experience with the design, manufacture, and application of individualized 3D printed mallet finger splints. The splints were found to provide advantages akin to traditional thermoplastic splints, with the addition of being low cost, easy to manufacture, and environmentally friendly.
Project description:A versatile method is reported for the manufacturing of antimicrobial (AM) surgery equipment utilising fused deposition modelling (FDM), three-dimensional (3D) printing and sonochemistry thin-film deposition technology. A surgical retractor was replicated from a commercial polylactic acid (PLA) thermoplastic filament, while a thin layer of silver (Ag) nanoparticles (NPs) was developed via a simple and scalable sonochemical deposition method. The PLA retractor covered with Ag NPs (PLA@Ag) exhibited vigorous AM properties examined by a reduction in Staphylococcus aureus (S. aureus), Pseudomonas aeruginosa (P. aeruginosa) and Escherichia coli (E. coli) bacteria viability (%) experiments at 30, 60 and 120 min duration of contact (p < 0.05). Scanning electron microscopy (SEM) showed the surface morphology of bare PLA and PLA@Ag retractor, revealing a homogeneous and full surface coverage of Ag NPs. X-Ray diffraction (XRD) analysis indicated the crystallinity of Ag nanocoating. Ultraviolent-visible (UV-vis) spectroscopy and transmission electron microscopy (TEM) highlighted the AgNP plasmonic optical responses and average particle size of 31.08 ± 6.68 nm. TEM images of the PLA@Ag crossection demonstrated the thickness of the deposited Ag nanolayer, as well as an observed tendency of AgNPs to penetrate though the outer surface of PLA. The combination of 3D printing and sonochemistry technology could open new avenues in the manufacturing of low-cost and on-demand antimicrobial surgery equipment.
Project description:This article describes fabrication of a customizable bioreactor, which comprises a perfusion system and coverslip-based tissue culture chamber that allow centimeter-scale vascularized or otherwise canalized tissue constructs to be maintained in weeks long static and/or perfusion culture at an exceptionally low cost, with intermittent live imaging and media sampling capabilities. The perfusion system includes a reusable polydimethylsiloxane (PDMS) lid generated from a three-dimensional (3D)-printed poly-lactic acid (PLA) mold and several lengths of perfusion tubing. The coverslip tissue culture chamber includes PDMS components built with 3D-printed PLA molds, as well as 3D-printed PLA frames and glass coverslips that house perfusable hydrogel constructs. As proof of concept, we fabricated a vascularized hydrogel construct, which was subjected to static and perfusion tissue culture, as well as flow studies using fluorescent beads and widefield fluorescent microscopy. This system can be readily reproduced, promoting the advancement of tissue engineering and regenerative medicine research.
Project description:BackgroundThis study evaluated and compared the shaping ability of four advanced single-file nickel-titanium (NiTi) systems during the preparation of curved second mesiobuccal (MB2) canals in maxillary first molar replicas fabricated by three-dimensional (3D) printing via micro-computed tomography (Micro-CT) imaging.MethodsA total of 60 3D-printed maxillary first molar replicas were constructed from one extracted tooth, with an angle of curvature ranging from 15° to 25°. The MB2 canals from these 60 replicas were divided into 4 groups of 15 replicas according to the canal instrumentation system used, namely, Waveone gold (WOG), Reciproc blue (RCB), XP-endo shaper (XPS) and M3-L. The specimens were scanned before and after preparation using Micro-CT. The pre- and post-instrumentation images of each specimen were superimposed, and the amount of resin removed, the change in surface area, the canal transportation, and centering ability were assessed using the Mimics software. Instrumentation time was also recorded. One-way analysis of variance and least significant difference (LSD) tests were used to statistically compare the groups. The significance level was set at 5%.ResultsInstrumentation time with M3-L was significantly longer than the other systems (P<0.05). The amount of resin removed and the change in surface area generated by the 4 systems were different at the apical, middle, and coronal thirds, and the total canal (P<0.05). Overall, WOG and XPS resulted in the less change than RCB and M3-L. There was no significant difference among the groups at the middle third regarding canal transportation and centering ability (P>0.05). However, a significant difference was found at the apical level (P<0.05), where RCB showed the poorest centering ability and the highest canal transportation (P<0.05). In addition, XPS resulted in the least canal transportation (P<0.05) at the coronal level, while there was no significant difference between the four groups in terms of centering ability.ConclusionsThe M3-L instrument required more time to prepare the curved MB2 canals compared with the other systems. Overall, WOG and XPS showed the least resin removal and surface area change. M3-L, XPS, and WOG instruments respected the original canal curvature better than RCB files.
Project description:BackgroundProsthetic hands with a myoelectric interface have recently received interest within the broader category of hand prostheses, but their high cost is a major barrier to use. Modern three-dimensional (3D) printing technology has enabled more widespread development and cost-effectiveness in the field of prostheses. The objective of the present study was to evaluate the clinical impact of a low-cost 3D-printed myoelectric-interface prosthetic hand on patients' daily life.MethodsA prospective review of all upper-arm transradial amputation amputees who used 3D-printed myoelectric interface prostheses (Mark V) between January 2016 and August 2017 was conducted. The functional outcomes of prosthesis usage over a 3-month follow-up period were measured using a validated method (Orthotics Prosthetics User Survey-Upper Extremity Functional Status [OPUS-UEFS]). In addition, the correlation between the length of the amputated radius and changes in OPUS-UEFS scores was analyzed.ResultsTen patients were included in the study. After use of the 3D-printed myoelectric single electromyography channel prosthesis for 3 months, the average OPUS-UEFS score significantly increased from 45.50 to 60.10. The Spearman correlation coefficient (r) of the correlation between radius length and OPUS-UEFS at the 3rd month of prosthetic use was 0.815.ConclusionsThis low-cost 3D-printed myoelectric-interface prosthetic hand with a single reliable myoelectrical signal shows the potential to positively impact amputees' quality of life through daily usage. The emergence of a low-cost 3D-printed myoelectric prosthesis could lead to new market trends, with such a device gaining popularity via reduced production costs and increased market demand.
Project description:This is a 7-years single institution study on low-cost cardiac three-dimensional (3D) printing based on the use of free open-source programs and affordable printers and materials. The process of 3D printing is based on several steps (image acquisition, segmentation, mesh optimization, slicing, and three-dimensional printing). The necessary technology and the processes to set up an affordable three-dimensional printing laboratory are hereby described in detail. Their impact on surgical and interventional planning, medical training, communication with patients and relatives, patients' perception on care, and new cardiac device development was analyzed. A total of 138 low-cost heart models were designed and printed from 2013 to 2020. All of them were from different congenital heart disease patients. The average time for segmentation and design of the hearts was 136 min; the average time for printing and cleaning the models was 13.5 h. The average production cost of the models was €85.7 per model. This is the most extensive series of 3D printed cardiac models published to date. In this study, the possibility of manufacturing three-dimensional printed heart models in a low-cost facility fulfilling the highest requirements from a technical and clinical point of view is demonstrated.
Project description:BACKGROUND: The lack of clear understanding of the association between sitting posture and adolescent musculoskeletal pain, might reflect invalid and/or unreliable posture measurement instruments. The psychometric properties of any new measurement instrument should be demonstrated prior to use for research or clinical purposes. This paper describes psychometric testing of a new three-dimensional (3D), portable, non-invasive posture analysis tool (3D-PAT), from sequential studies using a mannequin and high school students. METHODS: The first study compared the 3D-(X-, Y- and Z-) coordinates of reflective markers placed on a mannequin using the 3D-PAT, and the Vicon motion analysis system. This study also tested the reliability of taking repeated measures of the 3D-coordinates of the reflective markers. The second study determined the concurrent validity and test-retest reliability of the 3D-PAT measurements of nine sitting postural angles of high school students undertaking a standard computing task. In both studies, concordance correlation coefficients and Intraclass correlation coefficients described test-retest reliability, whilst Pearson product moment correlation coefficients and Bland-Altman plots demonstrated concurrent validity. RESULTS: The 3D-PAT provides reliable and valid 3D measurements of five of the nine postural angles i.e. head flexion, neck flexion, cranio-cervical angle, trunk flexion and head lateral bending in adolescents undertaking a standard task. CONCLUSIONS: The 3D-PAT is appropriate for research and clinical settings to measure five upper quadrant postural angles in three dimensions. As a measurement instrument it can provide further understanding of the relationship between sitting posture, changes to sitting posture and adolescent musculoskeletal pain.
Project description:A three-dimensional (3D)-printed customized bolus (3D bolus) can be used for radiotherapy application to irregular surfaces. However, bolus fabrication based on computed tomography (CT) scans is complicated and also delivers unwanted irradiation. Consequently, we fabricated a bolus using a 3D scanner and evaluated its efficacy. The head of an Alderson Rando phantom was scanned with a 3D scanner. The 3D surface data were exported and reconstructed with Geomagic Design X software. A 3D bolus of 5-mm thickness designed to fit onto the nose was printed with the use of rubber-like printing material, and a radiotherapy plan was developed. We successfully fabricated the customized 3D bolus, and further, a CT simulation indicated an acceptable fit of the 3D bolus to the nose. There was no air gap between the bolus and the phantom surface. The percent depth dose (PDD) curve of the phantom with the 3D bolus showed an enhanced surface dose when compared with that of the phantom without the bolus. The PDD of the 3D bolus was comparable with that of a commercial superflab bolus. The radiotherapy plan considering the 3D bolus showed improved target coverage when compared with that without the bolus. Thus, we successfully fabricated a customized 3D bolus for an irregular surface using a 3D scanner instead of a CT scanner.
Project description:MethodsAnonymized CT DICOM data was segmented to create a 3D model of the lumbar spine. The 3D model was modified, placed inside a digitally designed housing unit and fabricated on a desktop 3D printer using polylactic acid (PLA) filament. The model was filled with an echogenic solution of gelatin with psyllium fiber. Twenty-two staff anesthesiologists performed a spinal and epidural on the 3D printed simulator and a commercially available Simulab phantom. Participants evaluated the tactile and ultrasound imaging fidelity of both phantoms via Likert-scale questionnaire.ResultsThe 3D printed neuraxial phantom cost $13 to print and required 25 hours of non-supervised printing and 2 hours of assembly time. The 3D printed phantom was found to be less realistic to surface palpation than the Simulab phantom due to fragility of the silicone but had significantly better fidelity for loss of resistance, dural puncture and ultrasound imaging than the Simulab phantom.ConclusionLow-cost neuraxial phantoms with fidelity comparable to commercial models can be produced using CT data and low-cost infrastructure consisting of FLOS software and desktop 3D printers.