Unknown

Dataset Information

0

Continuous monitoring system for safe managements of CO2 storage and geothermal reservoirs.


ABSTRACT: We have developed a new continuous monitoring system based on small seismic sources and distributed acoustic sensing (DAS). The source system generates continuous waveforms with a wide frequency range. Because the signal timing is accurately controlled, stacking the continuous waveforms enhances the signal-to-noise ratio, allowing the use of a small seismic source to monitor extensive areas (multi-reservoir). Our field experiments demonstrated that the monitoring signal was detected at a distance of ~ 80 km, and temporal variations of the monitoring signal (i.e., seismic velocity) were identified with an error of < 0.01%. Through the monitoring, we identified pore pressure variations due to geothermal operations and rains. When we used seafloor cable for DAS measurements, we identified the monitoring signals at > 10 km far from the source in high-spatial resolution. This study demonstrates that multi-reservoir in an extensive area can be continuously monitored at a relatively low cost by combining our seismic source and DAS.

SUBMITTER: Tsuji T 

PROVIDER: S-EPMC8476502 | biostudies-literature | 2021 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Continuous monitoring system for safe managements of CO<sub>2</sub> storage and geothermal reservoirs.

Tsuji Takeshi T   Ikeda Tatsunori T   Matsuura Ryosuke R   Mukumoto Kota K   Hutapea Fernando Lawrens FL   Kimura Tsunehisa T   Yamaoka Koshun K   Shinohara Masanao M  

Scientific reports 20210927 1


We have developed a new continuous monitoring system based on small seismic sources and distributed acoustic sensing (DAS). The source system generates continuous waveforms with a wide frequency range. Because the signal timing is accurately controlled, stacking the continuous waveforms enhances the signal-to-noise ratio, allowing the use of a small seismic source to monitor extensive areas (multi-reservoir). Our field experiments demonstrated that the monitoring signal was detected at a distanc  ...[more]

Similar Datasets

| S-EPMC8695373 | biostudies-literature
| S-EPMC10209096 | biostudies-literature
| S-EPMC7780548 | biostudies-literature
| S-EPMC10250531 | biostudies-literature
| S-EPMC6540388 | biostudies-literature
| S-EPMC3258629 | biostudies-literature
| S-EPMC6283841 | biostudies-literature
| S-EPMC10587023 | biostudies-literature
| S-EPMC7899219 | biostudies-literature
| S-EPMC7847708 | biostudies-literature