Transcatheter aortic valve implantation in patients with a small aortic annulus: performance of supra-, intra- and infra-annular transcatheter heart valves.


ABSTRACT:

Background

A small aortic annulus is associated with increased risk of prosthesis-patient mismatch (PPM) after transcatheter aortic valve implantation (TAVI). Whether specific transcatheter heart valve (THV) designs yield superior hemodynamic performance in these small anatomies remains unclear.

Methods

Data from 8411 consecutive patients treated with TAVI from May 2012 to April 2019 at four German centers were retrospectively evaluated. A small aortic annulus was defined as multidetector computed tomography-derived annulus area < 400 mm2. TAVI was performed with a balloon-expanding intra-annular (Sapien-3, n = 288), self-expanding intra-annular (Portico, n = 110), self-expanding supra-annular (Evolut, n = 179 and Acurate-Neo, n = 428) and mechanically expanding infra-annular (Lotus, n = 64) THV according to local practice. PPM was defined as indexed effective orifice area ≤ 0.85cm2/m2.

Results

A small annulus was found in 1069 (12.7%) patients. PPM was detected in 38.3% overall with a higher prevalence after implantation of a balloon-expanding intra-annular or mechanically expanding infra-annular THV compared to self-expanding intra- and supra-annular THV. Multivariable analysis linked self-expanding THV (Evolut: Odds ratio [OR] 0.341, Acurate-Neo: OR 0.436, Portico: OR 0.291), postdilatation (OR 0.648) and age (OR 0.968) to lower rates of PPM, while aortic valve calcification was associated with an increased risk (OR 1.001). Paravalvular regurgitation > mild was more frequent after TAVI with self-expanding THV (p = 0.04).

Conclusion

In this large contemporary multicenter patient population, a substantial number of patients with a small aortic anatomy were left with PPM after TAVI. Self-expanding supra- and intra-annular THV demonstrated superior hemodynamics in these patients at risk, however at the cost of higher rates of residual paravalvular regurgitation.

SUBMITTER: Voigtlander L 

PROVIDER: S-EPMC8639544 | biostudies-literature | 2021 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Transcatheter aortic valve implantation in patients with a small aortic annulus: performance of supra-, intra- and infra-annular transcatheter heart valves.

Voigtländer Lisa L   Kim Won-Keun WK   Mauri Victor V   Goßling Alina A   Renker Matthias M   Sugiura Atsushi A   Linder Matthias M   Schmidt Tobias T   Schofer Niklas N   Westermann Dirk D   Reichenspurner Hermann H   Nickenig Georg G   Blankenberg Stefan S   Hamm Christian C   Conradi Lenard L   Adam Matti M   Sinning Jan-Malte JM   Seiffert Moritz M  

Clinical research in cardiology : official journal of the German Cardiac Society 20210813 12


<h4>Background</h4>A small aortic annulus is associated with increased risk of prosthesis-patient mismatch (PPM) after transcatheter aortic valve implantation (TAVI). Whether specific transcatheter heart valve (THV) designs yield superior hemodynamic performance in these small anatomies remains unclear.<h4>Methods</h4>Data from 8411 consecutive patients treated with TAVI from May 2012 to April 2019 at four German centers were retrospectively evaluated. A small aortic annulus was defined as multi  ...[more]

Similar Datasets

| S-EPMC8649494 | biostudies-literature
| S-EPMC5889984 | biostudies-literature
| S-EPMC5852276 | biostudies-literature
| S-EPMC9215259 | biostudies-literature
| S-EPMC6234484 | biostudies-other
| S-EPMC9207781 | biostudies-literature
| S-EPMC5590871 | biostudies-literature
| S-EPMC7977026 | biostudies-literature
| S-EPMC7925971 | biostudies-literature
| S-EPMC9700572 | biostudies-literature