Unknown

Dataset Information

0

Comparison of conventional, doppler and contrast-enhanced ultrasonography in differential diagnosis of ovarian masses: a systematic review and meta-analysis.


ABSTRACT:

Objectives

To assess the value of conventional, Doppler and contrast-enhanced ultrasonography (CEUS) (conventional ultrasonography (US), Doppler US and CEUS) for diagnosing ovarian cancer.

Design

Systematic review and meta-analysis.

Data sources

PubMed, Embase and the Cochrane Library were conducted for studies published until October 2021.

Eligibility criteria

Studies assessed the diagnostic value of conventional US, Doppler US or CEUS for detecting ovarian cancer, with no restrictions placed on published language and status.

Data extraction and synthesis

The study selection and data extraction were performed by two independent authors. The sensitivity, specificity, positive and negative likelihood ratio (PLR and NLR), diagnostic OR (DOR) and area under the receiver operating characteristic curve (AUC) were pooled using the bivariate generalised linear mixed model and random effects model.

Results

The meta-analysis included 72 studies and involved 9296 women who presented with ovarian masses. The pooled sensitivity, specificity, PLR, NLR, DOR and AUC for conventional US were 0.91 (95% CI: 0.87 to 0.94) and 0.87 (95% CI: 0.82 to 0.91), 6.87 (95% CI: 4.98 to 9.49) and 0.10 (95% CI: 0.07 to 0.15), 57.52 (95% CI: 36.64 to 90.28) and 0.95 (95% CI: 0.93 to 0.97), respectively. The sensitivity, specificity, PLR, NLR, DOR and AUC for Doppler US were 0.93 (95% CI: 0.91 to 0.95) and 0.85 (95% CI: 0.80 to 0.89), 6.10 (95% CI: 4.59 to 8.11) and 0.08 (95% CI: 0.06 to 0.11), 61.76 (95% CI: 39.99 to 95.37) and 0.96 (95% CI: 0.94 to 0.97), respectively. The pooled sensitivity, specificity, PLR, NLR, DOR and AUC for CEUS were 0.97 (95% CI: 0.92 to 0.99) and 0.92 (95% CI: 0.85 to 0.95), 11.47 (95% CI: 6.52 to 20.17) and 0.03 (95% CI: 0.01 to 0.09), 152.11 (95% CI: 77.77 to 297.51) and 0.99 (95% CI: 0.97 to 0.99), respectively. Moreover, the AUC values for conventional US (p=0.002) and Doppler US (p=0.005) were inferior to those of CEUS.

Conclusions

Conventional US, Doppler US and CEUS have a relatively high differential diagnostic value for differentiating between benign and malignant ovarian masses. The diagnostic performance of CEUS was superior to that of conventional US and Doppler US.

SUBMITTER: Xun L 

PROVIDER: S-EPMC8710872 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC4357383 | biostudies-literature