Ontology highlight
ABSTRACT: Background
The physiological effects of prone ventilation in ARDS patients have been discussed for a long time but have not been fully elucidated. Electrical impedance tomography (EIT) has emerged as a tool for bedside monitoring of pulmonary ventilation and perfusion, allowing the opportunity to obtain data. This study aimed to investigate the effect of prone positioning (PP) on ventilation-perfusion matching by contrast-enhanced EIT in patients with ARDS.Design
Monocenter prospective physiologic study.Setting
University medical ICU.Patients
Ten mechanically ventilated ARDS patients who underwent PP.Interventions
We performed EIT evaluation at the initiation of PP, 3 h after PP initiation and the end of PP during the first PP session.Measurements and main results
The regional distribution of ventilation and perfusion was analyzed based on EIT images and compared to the clinical variables regarding respiratory and hemodynamic status. Prolonged prone ventilation improved oxygenation in the ARDS patients. Based on EIT measurements, the distribution of ventilation was homogenized and dorsal lung ventilation was significantly improved by PP administration, while the effect of PP on lung perfusion was relatively mild, with increased dorsal lung perfusion observed. The ventilation-perfusion matched region was found to increase and correlate with the increased PaO2/FiO2 by PP, which was attributed mainly to reduced shunt in the lung.Conclusions
Prolonged prone ventilation increased dorsal ventilation and perfusion, which resulted in improved ventilation-perfusion matching and oxygenation.Trial registration
ClinicalTrials.gov, NCT04725227. Registered on 25 January 2021.
SUBMITTER: Wang YX
PROVIDER: S-EPMC9137443 | biostudies-literature | 2022 May
REPOSITORIES: biostudies-literature
Wang Yu-Xian YX Zhong Ming M Dong Min-Hui MH Song Jie-Qiong JQ Zheng Yi-Jun YJ Wu Wei W Tao Jia-le JL Zhu Ling L Zheng Xin X
Critical care (London, England) 20220527 1
<h4>Background</h4>The physiological effects of prone ventilation in ARDS patients have been discussed for a long time but have not been fully elucidated. Electrical impedance tomography (EIT) has emerged as a tool for bedside monitoring of pulmonary ventilation and perfusion, allowing the opportunity to obtain data. This study aimed to investigate the effect of prone positioning (PP) on ventilation-perfusion matching by contrast-enhanced EIT in patients with ARDS.<h4>Design</h4>Monocenter prosp ...[more]