Reversible Thermo-Responsive Valve for Microfluidic Paper-Based Analytical Devices.


ABSTRACT: Fluid control on a paper channel is necessary for analysis with multiple reagents, such as enzyme-linked immunosorbent assay (ELISA) in microfluidic paper-based analytical devices (µPADs). In this study, a thermo-responsive valve was fabricated by polymerizing N-isopropylacrylamide on a PVDF porous membrane by plasma-induced graft polymerization. The polymerized membrane was observed by scanning electron microscopy (SEM), and it was confirmed that more pores were closed at temperatures below 32 °C and more pores were opened at temperatures above 32 °C. Valve permeability tests confirmed that the proposed polymerized membrane was impermeable to water and proteins at temperatures below 32 °C and permeable to water at temperatures above 32 °C. The valve could also be reversibly and repeatedly opened and closed by changing the temperature near 32 °C. These results suggest that plasma-induced graft polymerization may be used to produce thermo-responsive valves that can be opened and closed without subsequent loss of performance. These results indicate that the thermo-responsive valve fabricated by plasma-induced graft polymerization could potentially be applied to ELISA with µPADs.

SUBMITTER: Toda H 

PROVIDER: S-EPMC9145873 | biostudies-literature | 2022 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Reversible Thermo-Responsive Valve for Microfluidic Paper-Based Analytical Devices.

Toda Hiroki H   Iwasaki Wataru W   Morita Nobutomo N   Motomura Taisei T   Takemura Kenshin K   Nagano Masaya M   Nakanishi Yoshitaka Y   Nakashima Yuta Y  

Micromachines 20220428 5


Fluid control on a paper channel is necessary for analysis with multiple reagents, such as enzyme-linked immunosorbent assay (ELISA) in microfluidic paper-based analytical devices (µPADs). In this study, a thermo-responsive valve was fabricated by polymerizing N-isopropylacrylamide on a PVDF porous membrane by plasma-induced graft polymerization. The polymerized membrane was observed by scanning electron microscopy (SEM), and it was confirmed that more pores were closed at temperatures below 32  ...[more]

Similar Datasets

| S-EPMC7071557 | biostudies-literature
| S-EPMC3931572 | biostudies-literature
| S-EPMC10499984 | biostudies-literature
| S-EPMC6386182 | biostudies-literature
| S-EPMC6189915 | biostudies-literature
| S-EPMC10377625 | biostudies-literature
| S-EPMC3065124 | biostudies-literature
| S-EPMC4036462 | biostudies-literature
| S-EPMC6536539 | biostudies-literature
| S-EPMC10649804 | biostudies-literature