Molecular detection of bacterial contamination in plasma using magnetic-based enrichment.


ABSTRACT: Bacterial contamination of blood products is a major problem in transfusion medicine, in terms of both morbidity and mortality. Platelets (PLTs) are stored at room temperature (under constant agitation) for more than 5 days, and bacteria can thus grow significantly from a low level to high titers. However, conventional methods like blood culture and lateral flow assay have disadvantages such as long detection time, low sensitivity, and the need for a large volume of blood components. We used real-time polymerase chain reaction (PCR) assays with antibiotic-conjugated magnetic nanobeads (MNBs) to detect enriched Gram-positive and -negative bacteria. The MNBs were coated with polyethylene glycol (PEG) to prevent aggregation by blood components. Over 80% of all bacteria were captured by the MNBs, and the levels of detection were 101 colony forming unit [CFU]/mL and 102 CFU/mL for Gram-positive and -negative bacteria, respectively. The detection time is < 3 h using only small volumes of blood components. Thus, compared to conventional methods, real-time PCR using MNBs allows for rapid detection with high sensitivity using only a small volume of blood components.

SUBMITTER: Lee J 

PROVIDER: S-EPMC9160056 | biostudies-literature | 2022 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Molecular detection of bacterial contamination in plasma using magnetic-based enrichment.

Lee Jinyeop J   Abafogi Abdurhaman Teyib AT   Oh Sujin S   Chang Ho Eun HE   Tepeng Wu W   Lee Daekyu D   Park Sungsu S   Park Kyoung Un KU   Hong Yun Ji YJ  

Scientific reports 20220601 1


Bacterial contamination of blood products is a major problem in transfusion medicine, in terms of both morbidity and mortality. Platelets (PLTs) are stored at room temperature (under constant agitation) for more than 5 days, and bacteria can thus grow significantly from a low level to high titers. However, conventional methods like blood culture and lateral flow assay have disadvantages such as long detection time, low sensitivity, and the need for a large volume of blood components. We used rea  ...[more]

Similar Datasets

| S-EPMC10913752 | biostudies-literature
| S-EPMC3525801 | biostudies-literature
| S-EPMC7441045 | biostudies-literature
| S-EPMC10888512 | biostudies-literature
2011-09-15 | E-MTAB-766 | biostudies-arrayexpress
| S-EPMC7279529 | biostudies-literature
| S-EPMC7616143 | biostudies-literature
| S-EPMC3910167 | biostudies-literature
| S-EPMC6838224 | biostudies-literature
| S-EPMC9064766 | biostudies-literature