ABSTRACT: Introduction
Late gadolinium enhancement (LGE) cardiac magnetic resonance imaging (MRI) can be used to detect postablation atrial scar (PAAS) but its reproducibility and reliability in clinical scans across different magnetic flux densities and scar detection methods are unknown.Methods
Patients (n = 45) having undergone two consecutive MRIs (3 months apart) on 3T and 1.5T scanners were studied. We compared PAAS detection reproducibility using four methods of thresholding: simple thresholding, Otsu thresholding, 3.3 standard deviations (SD) above blood pool (BP) mean intensity, and image intensity ratio (IIR). We performed a texture study by dividing the left atrial wall intensity histogram into deciles and evaluated the correlation of the same decile of the two scans as well as to a randomized distribution of intensities, quantified using Dice Similarity Coefficient (DSC).Results
The choice of scanner did not significantly affect the reproducibility. The scar detection performed by Otsu thresholding (DSC of 71.26 ± 8.34) resulted in a better correlation of the two scans compared with the methods of 3.3 SD above BP mean intensity (DSC of 57.78 ± 21.2, p < .001) and IIR above 1.61 (DSC of 45.76 ± 29.55, p <.001). Texture analysis showed that correlation only for voxels with intensities in deciles above the 70th percentile of wall intensity histogram was better than random distribution (p < .001).Conclusions
Our results demonstrate that clinical LGE-MRI can be reliably used for visualizing PAAS across different magnetic flux densities if the threshold is greater than 70th percentile of the wall intensity distribution. Also, atrial wall-based thresholding is better than BP-based thresholding for reproducible PAAS detection.
SUBMITTER: Kamali R
PROVIDER: S-EPMC9205620 | biostudies-literature | 2020 Nov
REPOSITORIES: biostudies-literature
Kamali Roya R Schroeder Joyce J DiBella Edward E Steinberg Benjamin B Han Frederick F Dosdall Derek J DJ Macleod Rob S RS Ranjan Ravi R
Journal of cardiovascular electrophysiology 20200928 11
<h4>Introduction</h4>Late gadolinium enhancement (LGE) cardiac magnetic resonance imaging (MRI) can be used to detect postablation atrial scar (PAAS) but its reproducibility and reliability in clinical scans across different magnetic flux densities and scar detection methods are unknown.<h4>Methods</h4>Patients (n = 45) having undergone two consecutive MRIs (3 months apart) on 3T and 1.5T scanners were studied. We compared PAAS detection reproducibility using four methods of thresholding: simple ...[more]