Unknown

Dataset Information

0

Long-term changes in corneal densitometry and associated factors following small incision lenticule extraction for moderate and high myopia.


ABSTRACT:

Purpose

To investigate long-term trends in corneal densitometry and associated influencing factors following small incision lenticule extraction (SMILE).

Methods

A comparative study was performed among 72 eyes of 38 patients undergoing SMILE. Eyes were divided into moderate myopia [mean spherical equivalent (SE),-4.22 ± 0.68D] and high myopia (mean SE,-7.63 ± 1.09 D) groups. Visual acuity, manifest refraction, corneal topography and corneal densitometry (CD) were evaluated preoperatively and 3 years postoperatively.

Results

The efficacy indices at last postoperative follow-up (42.47 ± 0.51 months) were 0.92 ± 0.21 and 0.97 ± 0.22, the safety indices were 1.12 ± 0.17 and 1.14 ± 0.21 for high and moderate myopia, respectively (all P > 0.05). CD values in the 0-6 mm zone of the posterior corneal layer was statistically significantly lower than the preoperative values in both groups. Postoperative CD values (0-2 mm zone) in the posterior layer of the high myopia group were statistically significantly lower than in the moderate myopia group (P = 0.025); CD values (2-6 mm zone) in the anterior layer were higher in the high myopia group (P = 0.026). Correlation analyses showed that CD values in the 0-2 mm middle layer were negatively correlated with lenticule thickness in high myopia (r = -0.411, P = 0.016); there was a negative correlation between the CD values (0-6 mm) and corneal oblique trefoil in this group (P < 0.05).

Conclusion

Corneal transparency in the 0-6 mm zone of the posterior cornea increased following SMILE in moderate and high myopia. Long-term CD values in high myopia may be correlated with oblique trefoil and lenticule thickness.

SUBMITTER: Xu C 

PROVIDER: S-EPMC9492929 | biostudies-literature | 2022

REPOSITORIES: biostudies-literature

altmetric image

Publications

Long-term changes in corneal densitometry and associated factors following small incision lenticule extraction for moderate and high myopia.

Xu Changqin C   Yang Dongmei D   Zhao Wuxiao W   Long Zhigang Z   Zhang Zhe Z   Shen Yang Y   Zhou Xingtao X   Zhao Jing J  

Frontiers in medicine 20220908


<h4>Purpose</h4>To investigate long-term trends in corneal densitometry and associated influencing factors following small incision lenticule extraction (SMILE).<h4>Methods</h4>A comparative study was performed among 72 eyes of 38 patients undergoing SMILE. Eyes were divided into moderate myopia [mean spherical equivalent (SE),-4.22 ± 0.68D] and high myopia (mean SE,-7.63 ± 1.09 D) groups. Visual acuity, manifest refraction, corneal topography and corneal densitometry (CD) were evaluated preoper  ...[more]

Similar Datasets

| S-EPMC7773189 | biostudies-literature
| S-EPMC9885585 | biostudies-literature
| S-EPMC10631666 | biostudies-literature
| S-EPMC10805804 | biostudies-literature
| S-EPMC7681246 | biostudies-literature
| S-EPMC9911227 | biostudies-literature
| S-EPMC4249972 | biostudies-literature
| S-EPMC4777367 | biostudies-literature
| S-EPMC5510831 | biostudies-literature
| S-EPMC7856947 | biostudies-literature