Unknown

Dataset Information

0

DDA-imaging with structural identification of lipid molecules on an Orbitrap Velos Pro mass spectrometer.


ABSTRACT: Matrix-assisted laser desorption/ionization-mass spectrometry imaging (MALDI-MSI) is a useful technique for visualizing the spatial distribution of lipid molecules in tissues. Nevertheless, the use of MSI to investigate local lipid metabolic hallmarks has until recently been hampered by a lack of adequate technology that supports confident lipid identification. This limitation was recently mitigated by the development of DDA-imaging technology where high-resolution MSI is combined with parallel acquisition of lipid tandem MS2 spectra on a hybrid ion trap-Orbitrap Elite mass spectrometer featuring a resolving power of 240,000 and a scan time of 1 s. Here, we report the key tenets related to successful transfer of the DDA-imaging technology onto an Orbitrap Velos Pro instrument featuring a resolving power of 120,000 and a scan time of 2 s. Through meticulous performance assessments and method optimization, we tuned the DDA-imaging method to be able to confidently identify 73 molecular lipid species in mouse brain sections and demonstrate that the performance of the technology is comparable with DDA-imaging on the Orbitrap Elite. Altogether, our work shows that DDA-imaging on the Orbitrap Velos Pro instrument can serve as a robust workhorse for lipid imaging in routine applications.

SUBMITTER: Khalil SM 

PROVIDER: S-EPMC9541402 | biostudies-literature | 2022 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

DDA-imaging with structural identification of lipid molecules on an Orbitrap Velos Pro mass spectrometer.

Khalil Saleh M SM   Sprenger Richard R RR   Hermansson Martin M   Ejsing Christer S CS  

Journal of mass spectrometry : JMS 20220901 9


Matrix-assisted laser desorption/ionization-mass spectrometry imaging (MALDI-MSI) is a useful technique for visualizing the spatial distribution of lipid molecules in tissues. Nevertheless, the use of MSI to investigate local lipid metabolic hallmarks has until recently been hampered by a lack of adequate technology that supports confident lipid identification. This limitation was recently mitigated by the development of DDA-imaging technology where high-resolution MSI is combined with parallel  ...[more]

Similar Datasets

| S-EPMC3817719 | biostudies-literature
| S-EPMC3202985 | biostudies-literature
| S-EPMC3518128 | biostudies-literature
| S-EPMC6211177 | biostudies-literature
| S-EPMC5799867 | biostudies-literature
| S-EPMC10326918 | biostudies-literature
| S-EPMC2556025 | biostudies-literature
| S-EPMC2953918 | biostudies-literature
| S-EPMC11327265 | biostudies-literature
| S-EPMC3562392 | biostudies-literature