Magnetic resonance imaging reveals possible cause of diplopia after Baerveldt glaucoma implantation.


ABSTRACT:

Purpose

To assess if ocular motility impairment, and the ensuing diplopia, after Baerveldt Glaucoma device (BGI) implantation, is related to the presence of a large fluid reservoir (bleb), using Magnetic Resonance Imaging (MRI).

Methods

In a masked observational study (CCMO-registry number: NL65633.058.18), the eyes of 30 glaucoma patients with (n = 12) or without diplopia (n = 18) who had previously undergone BGI implantation were scanned with a 7 Tesla MRI-scanner. The substructures of the BGI-complex, including both blebs and plate, were segmented in 3D. Primary outcomes were a comparison of volume and height of the BGI-complex between patients with and without diplopia. Comparisons were performed by using an unpaired t-test, Fisher's Exact or Mann-Whitney test. Correlations were determined by using Spearman correlation.

Results

The median volume and height of the BGI-complex was significantly higher in patients with compared to patients without diplopia (p = 0.007 and p = 0.025, respectively). Six patients had an excessively large total bleb volume (median of 1736.5mm3, interquartile range 1486.3-1933.9mm3), four of whom experienced diplopia (33% of the diplopia patients). Fibrotic strands through the BGI plate, intended to limit the height of the bleb, could be visualized but were not related to diplopia (75% versus 88%; p = 0.28).

Conclusions

With MRI, we show that in a significant number of diplopia cases a large bleb is present in the orbit. Given the large volume of these blebs, they are a likely explanation of the development of diplopia in at least some of the patients with diplopia after BGI implantation. Additionally, the MR-images confirm the presence of fibrotic strands. As these strands are also visible in patients with a large bleb, they are apparently not sufficient to restrict the bleb height.

SUBMITTER: Islamaj E 

PROVIDER: S-EPMC9584370 | biostudies-literature | 2022

REPOSITORIES: biostudies-literature

altmetric image

Publications

Magnetic resonance imaging reveals possible cause of diplopia after Baerveldt glaucoma implantation.

Islamaj Esma E   Van Vught Luc L   Jordaan-Kuip Caroline P CP   Vermeer Koenraad A KA   Ferreira Teresa A TA   De Waard Peter W T PWT   Lemij Hans G HG   Beenakker Jan-Willem M JM  

PloS one 20221020 10


<h4>Purpose</h4>To assess if ocular motility impairment, and the ensuing diplopia, after Baerveldt Glaucoma device (BGI) implantation, is related to the presence of a large fluid reservoir (bleb), using Magnetic Resonance Imaging (MRI).<h4>Methods</h4>In a masked observational study (CCMO-registry number: NL65633.058.18), the eyes of 30 glaucoma patients with (n = 12) or without diplopia (n = 18) who had previously undergone BGI implantation were scanned with a 7 Tesla MRI-scanner. The substruct  ...[more]

Similar Datasets

| S-EPMC5595874 | biostudies-literature
| S-EPMC10024771 | biostudies-literature
| S-EPMC6062117 | biostudies-literature
| S-EPMC10750127 | biostudies-literature
| S-EPMC9283577 | biostudies-literature
2018-12-01 | GSE101908 | GEO
| S-EPMC10661558 | biostudies-literature
2023-11-03 | GSE239379 | GEO
| S-EPMC6544345 | biostudies-literature
| S-EPMC10293048 | biostudies-literature