Unknown

Dataset Information

0

Quantitative fluorogenic PCR assay for measuring ovine herpesvirus 2 replication in sheep.


ABSTRACT: A fluorogenic PCR specific for ovine herpesvirus 2 (OvHV-2) DNA was developed and compared to a previously established conventional seminested PCR. Testing of a total of 152 blood samples from both positive and negative animals revealed that the results of both assays corresponded to each other in 100% of the cases. A second fluorogenic PCR for genomic sheep DNA was required to normalize the quantity of viral DNA in the sample. Separate standard curves had to be constructed for each PCR. The analytical sensitivity of the new PCRs ranged between at least 10 copies and sometimes even 1 copy of target DNA per reaction mixture. In dilution series of the target DNAs, linear decreases of the signals were observed over 7 orders of magnitude. Thus, it was possible to calculate the amounts of viral DNA in relation to the amounts of cellular DNA by normalizing the absolute quantity of OvHV-2 DNA with the amount of genomic sheep DNA. By this technique, it was possible for the first time to quantitatively characterize the course of OvHV-2 replication in naturally infected sheep.

SUBMITTER: Hussy D 

PROVIDER: S-EPMC96020 | biostudies-literature | 2001 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Quantitative fluorogenic PCR assay for measuring ovine herpesvirus 2 replication in sheep.

Hüssy D D   Stäuber N N   Leutenegger C M CM   Rieder S S   Ackermann M M  

Clinical and diagnostic laboratory immunology 20010101 1


A fluorogenic PCR specific for ovine herpesvirus 2 (OvHV-2) DNA was developed and compared to a previously established conventional seminested PCR. Testing of a total of 152 blood samples from both positive and negative animals revealed that the results of both assays corresponded to each other in 100% of the cases. A second fluorogenic PCR for genomic sheep DNA was required to normalize the quantity of viral DNA in the sample. Separate standard curves had to be constructed for each PCR. The ana  ...[more]

Similar Datasets

| S-EPMC88385 | biostudies-literature
| S-EPMC8318789 | biostudies-literature
| S-EPMC2168119 | biostudies-literature
| S-EPMC10056083 | biostudies-literature
| S-EPMC87527 | biostudies-literature
| S-EPMC3709743 | biostudies-literature
| S-EPMC3367212 | biostudies-literature
| S-EPMC7527251 | biostudies-literature
| S-EPMC2687043 | biostudies-literature
| S-EPMC86487 | biostudies-literature