Evaluation of Quantitative Platforms for Single Target Mass Spectrometry Imaging.


ABSTRACT: (1) Imaging of pharmaceutical compounds in tissue is an increasingly important subsection of Mass Spectrometry Imaging (MSI). Identifying proper target engagement requires MS platforms with high sensitivity and spatial resolution. Three prominent categories of drugs are small molecule drugs, antibody-drug conjugate payloads, and protein degraders. (2) We tested six common MSI platforms for their limit of detection (LoD) on a representative compound for each category: a Matrix-Assisted Laser Desorption/Ionization (MALDI) Fourier Transform Ion Cyclotron, a MALDI-2 Time-of-Flight (ToF), a MALDI-2 Trapped Ion Mobility Spectrometry ToF, a Desorption Electrospray Ionization Orbitrap, and 2 Atmospheric Pressure-MALDI Triple Quadrupoles. Samples were homogenized tissue mimetic models of rat liver spiked with known concentrations of analytes. (3) We found that the AP-MALDI-QQQ platform outperformed all 4 competing platforms by a minimum of 2- to 52-fold increase in LoD for representative compounds from each category of pharmaceutical. (4) AP-MALDI-QQQ platforms are effective, cost-efficient mass spectrometers for the identification of targeted analytes of interest.

SUBMITTER: Bowman AP 

PROVIDER: S-EPMC9609477 | biostudies-literature | 2022 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Evaluation of Quantitative Platforms for Single Target Mass Spectrometry Imaging.

Bowman Andrew P AP   Sawicki James J   Talaty Nari N NN   Buck Wayne R WR   Yang Junhai J   Wagner David S DS  

Pharmaceuticals (Basel, Switzerland) 20220923 10


(1) Imaging of pharmaceutical compounds in tissue is an increasingly important subsection of Mass Spectrometry Imaging (MSI). Identifying proper target engagement requires MS platforms with high sensitivity and spatial resolution. Three prominent categories of drugs are small molecule drugs, antibody-drug conjugate payloads, and protein degraders. (2) We tested six common MSI platforms for their limit of detection (LoD) on a representative compound for each category: a Matrix-Assisted Laser Deso  ...[more]

Similar Datasets

| S-EPMC7275808 | biostudies-literature
2005-09-20 | GSE2744 | GEO
| S-EPMC6854904 | biostudies-literature
| S-EPMC11007677 | biostudies-literature
| S-EPMC10445330 | biostudies-literature
| S-EPMC7806610 | biostudies-literature
2016-11-15 | GSE89818 | GEO
| S-EPMC8762722 | biostudies-literature
| S-EPMC6103225 | biostudies-literature
| S-EPMC6021760 | biostudies-literature