Quantitative spatial mapping of tissue water and lipid content using spatial frequency domain imaging in the 900- to 1000-nm wavelength region.


ABSTRACT:

Significance

Water and lipid are key participants of many biological processes, but there are few label-free, non-contact optical methods that can spatially map these components in-vivo. Shortwave infrared meso-patterned imaging (SWIR-MPI) is an emerging technique that successfully addresses this need. However, it requires a dedicated SWIR camera to probe the 900- to 1300-nm wavelength region, which hinders practical translation of the technology.

Aim

Compared with SWIR-MPI, we aim to develop a new technique that can dramatically reduce the cost in detector while maintaining high accuracy for the quantification of tissue water and lipid content.

Approach

By utilizing water and lipid absorption features in the 900- to 1000-nm wavelength region as well as optimal wavelength and spatial frequency combinations, we develop a new imaging technique based on spatial frequency domain imaging to quantitatively map tissue water and lipid content using a regular silicon-based camera.

Results

The proposed method is validated with a phantom study, which shows average error of 0.9 ± 1.2 % for water content estimation, and -0.4 ± 0.7 % for lipid content estimation, respectively. The proposed method is also demonstrated for ex vivo porcine tissue lipid mapping as well as in-vivo longitudinal water content monitoring.

Conclusions

The proposed technique enables spatial mapping of tissue water and lipid content with the cost in detector reduced by two orders of magnitude compared with SWIR-MPI while maintaining high accuracy. The experimental results highlight the potential of this technique for substantial impact in both scientific and industrial applications.

SUBMITTER: Song B 

PROVIDER: S-EPMC9612091 | biostudies-literature | 2022 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Quantitative spatial mapping of tissue water and lipid content using spatial frequency domain imaging in the 900- to 1000-nm wavelength region.

Song Bowen B   Yin Xinman X   Fan Yubo Y   Zhao Yanyu Y  

Journal of biomedical optics 20221001 10


<h4>Significance</h4>Water and lipid are key participants of many biological processes, but there are few label-free, non-contact optical methods that can spatially map these components in-vivo. Shortwave infrared meso-patterned imaging (SWIR-MPI) is an emerging technique that successfully addresses this need. However, it requires a dedicated SWIR camera to probe the 900- to 1300-nm wavelength region, which hinders practical translation of the technology.<h4>Aim</h4>Compared with SWIR-MPI, we ai  ...[more]

Similar Datasets

| S-EPMC3031903 | biostudies-other
| S-EPMC9010459 | biostudies-literature
| S-EPMC4079120 | biostudies-literature
| S-EPMC7441041 | biostudies-literature
| S-EPMC6848079 | biostudies-literature
| S-EPMC6096386 | biostudies-literature
| S-EPMC9555292 | biostudies-literature
| S-EPMC6688645 | biostudies-literature
| S-EPMC6890363 | biostudies-literature
| S-EPMC6774672 | biostudies-literature