Unknown

Dataset Information

0

Evaluation of Intra- and Interobserver Reproducibility of the New AO/OTA Classification for Distal Radius Fractures Compared with the Fernandez Classification.


ABSTRACT: Objective  To evaluate the inter- and intraobserver reliability and reproducibility of the new AO/OTA 2018 classification for distal radius fractures and to compare it with the Fernandez classification system. Method  A questionnaire was applied in the Qualtrics software on 10 specialists in hand surgery who classified 50 radiographs of distal radius fractures according to the Fernandez and AO/OTA 2018 classifications and, subsequently, indicated their treatment. The questionnaire was applied in time T0 and repeated after 4 weeks (t1) . The mean agreement between the answers, and the reliability and inter- and intraobserver reproducibility were analyzed using kappa indexes. Results  The mean interobserver agreement in the Fernandez classification was 76.4, and it was 59.2% in the AO/OTA 2018 classification. The intraobserver agreements were 77.3 and 56.6%, respectively. The inter- and intraobserver kappa indexes for the Fernandez classification were 0.57 and 0.55, respectively, and, in the AO/OTA 2018 classification, they were 0.34 and 0.31, respectively. Conclusion  The AO/OTA 2018 classification showed a low intra- and interobserver reproducibility when compared with the Fernandez classification. However, both classifications have low intra- and interobserver indexes. Although the Fernandez classification did not obtain excellent results, it remains with better agreement for routine use.

SUBMITTER: Carula BC 

PROVIDER: S-EPMC9757955 | biostudies-literature | 2022 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Evaluation of Intra- and Interobserver Reproducibility of the New AO/OTA Classification for Distal Radius Fractures Compared with the Fernandez Classification.

Carula Beatriz Canhoto BC   Giostri Giana Silveira GS   Bebber Fabiana F   Batista Marianna Fergutz Dos S MFDS   Silva Flaviana Busignani da FBD   Novak Eduardo Murilo EM  

Revista brasileira de ortopedia 20220926 6


<b>Objective</b>  To evaluate the inter- and intraobserver reliability and reproducibility of the new AO/OTA 2018 classification for distal radius fractures and to compare it with the Fernandez classification system. <b>Method</b>  A questionnaire was applied in the Qualtrics software on 10 specialists in hand surgery who classified 50 radiographs of distal radius fractures according to the Fernandez and AO/OTA 2018 classifications and, subsequently, indicated their treatment. The questionnaire  ...[more]

Similar Datasets

| S-EPMC5694815 | biostudies-literature
| S-EPMC7067934 | biostudies-literature
| S-EPMC10801158 | biostudies-literature
| S-EPMC9073806 | biostudies-literature
| S-EPMC8016258 | biostudies-literature
| S-EPMC5024498 | biostudies-literature
| S-EPMC7879530 | biostudies-literature
| S-EPMC8506535 | biostudies-literature
| S-EPMC10536142 | biostudies-literature
| S-EPMC2724614 | biostudies-other