ABSTRACT: Background
Coincidental extracardiac findings with increased perfusion were reported during myocardial perfusion imaging (MPI) with various retention radiotracers. Clinical parametric O-15-H2O PET MPI yielding quantitative measures of myocardial blood flow (MBF) was recently implemented at our facility. We aim to explore whether similar extracardiac findings are observed using O-15-H2O.Methods and results
All patients (2963) were scanned with O-15-H2O PET MPI according to international guidelines and extracardiac findings were collected. In contrast to parametric O-15-H2O MBF images, extracardiac perfusion was assessed using summed images. Biopsy histopathology and other imaging modalities served as reference standards. Various malignant lesions with increased perfusion were detected, including lymphomas, large-celled neuroendocrine tumour, breast, and lung cancer plus metastases from colonic and renal cell carcinomas. Furthermore, inflammatory and hyperplastic benign conditions with increased perfusion were observed: rib fractures, gynecomastia, atelectasis, sarcoidosis, pneumonia, chronic lung inflammation and fibrosis, benign lung nodule, chronic diffuse lung infiltrates, pleural plaques and COVID-19 infiltrates.Conclusions
Malignant and benign extracardiac coincidental findings with increased perfusion are readily visible and frequently seen on O-15-H2O PET MPI. We recommend evaluating the summed O-15-H2O PET images in addition to the low-dose CT attenuation images.
SUBMITTER: Jochumsen MR
PROVIDER: S-EPMC9812748 | biostudies-literature | 2023 Jan
REPOSITORIES: biostudies-literature
Jochumsen Mads Ryø MR Overgaard David Lyse DL Vendelbo Mikkel Holm MH Madsen Michael Alle MA Tolbod Lars Poulsen LP Gormsen Lars Christian LC Barkholt Trine Ørhøj TØ
Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology 20230105 4
<h4>Background</h4>Coincidental extracardiac findings with increased perfusion were reported during myocardial perfusion imaging (MPI) with various retention radiotracers. Clinical parametric O-15-H<sub>2</sub>O PET MPI yielding quantitative measures of myocardial blood flow (MBF) was recently implemented at our facility. We aim to explore whether similar extracardiac findings are observed using O-15-H<sub>2</sub>O.<h4>Methods and results</h4>All patients (2963) were scanned with O-15-H<sub>2</s ...[more]