Unknown

Dataset Information

0

Smartphone-based cardiac implantable electronic device remote monitoring: improved compliance and connectivity.


ABSTRACT:

Aims

Remote monitoring (RM) is the standard of care for follow up of patients with cardiac implantable electronic devices. The aim of this study was to compare smartphone-based RM (SM-RM) using patient applications (myMerlinPulse™ app) with traditional bedside monitor RM (BM-RM).

Methods and results

The retrospective study included de-identified US patients who received either SM-RM or BM-RM capable of implantable cardioverter defibrillators or cardiac resynchronization therapy defibrillators (Abbott, USA). Patients in SM-RM and BM-RM groups were propensity-score matched on age and gender, device type, implant year, and month. Compliance with RM was quantified as the proportion of patients enrolling in the RM system (Merlin.net™) and transmitting data at least once. Connectivity was measured by the median number of days between consecutive transmissions per patient. Of the initial 9714 patients with SM-RM and 26 679 patients with BM-RM, 9397 patients from each group were matched. Remote monitoring compliance was higher in SM-RM; significantly more patients with SM-RM were enrolled in RM compared with BM-RM (94.4 vs. 85.0%, P < 0.001), similar number of patients in the SM-RM group paired their device (95.1 vs. 95.0%, P = 0.77), but more SM-RM patients transmitted at least once (98.1 vs. 94.3%, P < 0.001). Connectivity was significantly higher in the SM-RM, with patients transmitting data every 1.2 (1.1, 1.7) vs. every 1.7 (1.5, 2.0) days with BM-RM (P < 0.001) and remained better over time. Significantly more SM-RM patients utilized patient-initiated transmissions compared with BM-RM (55.6 vs. 28.1%, P < 0.001).

Conclusion

In this large real-world study, patients with SM-RM demonstrated improved compliance and connectivity compared with BM-RM.

SUBMITTER: Manyam H 

PROVIDER: S-EPMC9890086 | biostudies-literature | 2023 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Smartphone-based cardiac implantable electronic device remote monitoring: improved compliance and connectivity.

Manyam Harish H   Burri Haran H   Casado-Arroyo Ruben R   Varma Niraj N   Lennerz Carsten C   Klug Didier D   Carr-White Gerald G   Kolli Kranthi K   Reyes Ignacio I   Nabutovsky Yelena Y   Boriani Giuseppe G  

European heart journal. Digital health 20221111 1


<h4>Aims</h4>Remote monitoring (RM) is the standard of care for follow up of patients with cardiac implantable electronic devices. The aim of this study was to compare smartphone-based RM (SM-RM) using patient applications (myMerlinPulse™ app) with traditional bedside monitor RM (BM-RM).<h4>Methods and results</h4>The retrospective study included de-identified US patients who received either SM-RM or BM-RM capable of implantable cardioverter defibrillators or cardiac resynchronization therapy de  ...[more]

Similar Datasets

| S-EPMC9276406 | biostudies-literature
| S-EPMC8824524 | biostudies-literature
| S-EPMC11671946 | biostudies-literature
| S-EPMC7183665 | biostudies-literature
| S-EPMC10422690 | biostudies-literature
| S-EPMC8129436 | biostudies-literature
| S-EPMC7843075 | biostudies-literature
| S-EPMC4939310 | biostudies-other
| S-EPMC7581580 | biostudies-literature