Specimen-displacement correction for powder X-ray diffraction in Debye-Scherrer geometry with a flat area detector.


ABSTRACT: The effect of small changes in the speci-men-to-detector distance on the unit-cell parameters is examined for synchrotron powder diffraction in Debye-Scherrer (transmission) geometry with a flat area detector. An analytical correction equation is proposed to fix the shift in 2θ values due to speci-men capillary displacement. This equation does not require the use of an internal reference material, is applied during the Rietveld refinement step, and is analogous to the speci-men-displacement correction equations for Bragg-Brentano and curved-detector Debye-Scherrer geometry experiments, but has a different functional form. The 2θ correction equation is compared with another speci-men-displacement correction based on the use of an internal reference material in which new integration and calibration parameters of area-detector images are determined. Example data sets showing the effect of a 3.3 mm speci-men displacement on the unit-cell parameters for 25°C CeO2, including both types of displacement correction, are described. These experiments were performed at powder X-ray diffraction beamlines at the National Synchrotron Light Source II at Brookhaven National Laboratory and the Advanced Photon Source at Argonne National Laboratory.

SUBMITTER: Hulbert BS 

PROVIDER: S-EPMC9901925 | biostudies-literature | 2023 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Specimen-displacement correction for powder X-ray diffraction in Debye-Scherrer geometry with a flat area detector.

Hulbert Benjamin S BS   Kriven Waltraud M WM  

Journal of applied crystallography 20230201 Pt 1


The effect of small changes in the speci-men-to-detector distance on the unit-cell parameters is examined for synchrotron powder diffraction in Debye-Scherrer (transmission) geometry with a flat area detector. An analytical correction equation is proposed to fix the shift in 2θ values due to speci-men capillary displacement. This equation does not require the use of an internal reference material, is applied during the Rietveld refinement step, and is analogous to the speci-men-displacement corr  ...[more]

Similar Datasets

| S-EPMC10161894 | biostudies-literature
| S-EPMC7842216 | biostudies-literature
| S-EPMC2924792 | biostudies-other
| S-EPMC5414395 | biostudies-literature
| S-EPMC8366427 | biostudies-literature
| S-EPMC10077857 | biostudies-literature
| S-EPMC4793152 | biostudies-literature
| S-EPMC8366421 | biostudies-literature
| S-EPMC10611698 | biostudies-literature
| S-EPMC8005348 | biostudies-literature