Unknown

Dataset Information

0

Probing sub-5 Angstrom micropores in carbon for precise light olefin/paraffin separation.


ABSTRACT: Olefin/paraffin separation is an important but challenging and energy-intensive process in petrochemical industry. The realization of carbons with size-exclusion capability is highly desirable but rarely reported. Herein, we report polydopamine-derived carbons (PDA-Cx, where x refers to the pyrolysis temperature) with tailorable sub-5 Å micropore orifices together with larger microvoids by one-step pyrolysis. The sub-5 Å micropore orifices centered at 4.1-4.3 Å in PDA-C800 and 3.7-4.0 Å in PDA-C900 allow the entry of olefins while entirely excluding their paraffin counterparts, performing a precise cut-off to discriminate olefin/paraffin with sub-angstrom discrepancy. The larger voids enable high C2H4 and C3H6 capacities of 2.25 and 1.98 mmol g-1 under ambient conditions, respectively. Breakthrough experiments confirm that a one-step adsorption-desorption process can obtain high-purity olefins. Inelastic neutron scattering further reveals the host-guest interaction of adsorbed C2H4 and C3H6 molecules in PDA-Cx. This study opens an avenue to exploit the sub-5 Å micropores in carbon and their desirable size-exclusion effect.

SUBMITTER: Du S 

PROVIDER: S-EPMC9981619 | biostudies-literature | 2023 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Probing sub-5 Ångstrom micropores in carbon for precise light olefin/paraffin separation.

Du Shengjun S   Huang Jiawu J   Ryder Matthew R MR   Daemen Luke L LL   Yang Cuiting C   Zhang Hongjun H   Yin Panchao P   Lai Yuyan Y   Xiao Jing J   Dai Sheng S   Chen Banglin B  

Nature communications 20230302 1


Olefin/paraffin separation is an important but challenging and energy-intensive process in petrochemical industry. The realization of carbons with size-exclusion capability is highly desirable but rarely reported. Herein, we report polydopamine-derived carbons (PDA-Cx, where x refers to the pyrolysis temperature) with tailorable sub-5 Å micropore orifices together with larger microvoids by one-step pyrolysis. The sub-5 Å micropore orifices centered at 4.1-4.3 Å in PDA-C800 and 3.7-4.0 Å in PDA-C  ...[more]

Similar Datasets

| S-EPMC8449386 | biostudies-literature
| S-EPMC6950670 | biostudies-literature
| S-EPMC10799885 | biostudies-literature
| S-EPMC6428864 | biostudies-literature
| S-EPMC7539199 | biostudies-literature
| S-EPMC7453017 | biostudies-literature
| S-EPMC8010088 | biostudies-literature
| S-EPMC6465289 | biostudies-literature
| S-EPMC9701225 | biostudies-literature
| S-EPMC7801458 | biostudies-literature