Unknown

Dataset Information

0

Reproducibility of volumetric intravascular ultrasound radiofrequency-based analysis of coronary plaque composition in vivo.


ABSTRACT: Intravascular ultrasound radiofrequency (RF-IVUS) data permit the analysis of coronary plaque composition in vivo and is used as an endpoint of ongoing pharmacological intervention trials. We assessed the reproducibility of volumetric RF-IVUS analyses in mild-to-moderately diseased atherosclerotic human coronary arteries in vivo. A total of 9,212 IVUS analyses on cross-sectional IVUS frames was performed to evaluate the reproducibility of volumetric RF-IVUS measurements in 33 coronary segments with a length of 27 +/- 7 mm. For vessel, lumen, and plaque + media volume the relative measurement differences (P = NS for all) were (A = intraobserver comparison, same pullback) -0.40 +/- 1.0%; -0.48 +/- 1.4%; -0.35 +/- 1.6%, (B = intraobserver comparison, repeated pullback) -0.42 +/- 1.2%; -0.52 +/- 1.8%; -0.43 +/- 4.5% (C = interobserver comparison, same pullback) 0.71 +/- 1.8%; 0.71 +/- 2.2%, and 0.89 +/- 5.0%, respectively. For fibrous, fibro-lipidic, calcium, and necrotic-core volumes the relative measurement differences (P = NS for all) were (A) 0.45 +/- 2.1%; -1.12 +/- 4.9%; -0.84 +/- 2.1%; -0.22 +/- 1.8%, (B) 1.40 +/- 4.1%; 1.26 +/- 6.7%; 2.66 +/- 7.4%; 0.85 +/- 4.4%, and (C) -1.60 +/- 4.9%; 3.85 +/- 8.2%; 1.66 +/- 7.5%, and -1.58 +/- 4.7%, respectively. Of note, necrotic-core volume showed on average the lowest measurement variability. Thus, in mild-to-moderate atherosclerotic coronary artery disease the reproducibility of volumetric compositional RF-IVUS measurements from the same pullback is relatively high, but lower than the reproducibility of geometrical IVUS measurements. Measurements from repeated pullbacks and by different observers show acceptable reproducibilities; the volumetric measurement of the necrotic-core shows on average the highest reproducibility of the compositional RF-IVUS measurements.

SUBMITTER: Hartmann M 

PROVIDER: S-EPMC2831183 | biostudies-other | 2009 Jan

REPOSITORIES: biostudies-other

altmetric image

Publications

Reproducibility of volumetric intravascular ultrasound radiofrequency-based analysis of coronary plaque composition in vivo.

Hartmann Marc M   Mattern Eline S K ES   Huisman Jennifer J   van Houwelingen Gert K GK   de Man Frits H A F FH   Stoel Martin G MG   Danse Peter W PW   Louwerenburg Hans W HW   von Birgelen Clemens C  

The international journal of cardiovascular imaging 20080813 1


Intravascular ultrasound radiofrequency (RF-IVUS) data permit the analysis of coronary plaque composition in vivo and is used as an endpoint of ongoing pharmacological intervention trials. We assessed the reproducibility of volumetric RF-IVUS analyses in mild-to-moderately diseased atherosclerotic human coronary arteries in vivo. A total of 9,212 IVUS analyses on cross-sectional IVUS frames was performed to evaluate the reproducibility of volumetric RF-IVUS measurements in 33 coronary segments w  ...[more]

Similar Datasets

| S-EPMC6173335 | biostudies-literature
| S-EPMC4619630 | biostudies-literature
| S-EPMC6824266 | biostudies-literature
| S-EPMC5091909 | biostudies-literature
| S-EPMC4520465 | biostudies-literature
| S-EPMC5837649 | biostudies-literature
| S-EPMC7013999 | biostudies-literature
| S-EPMC6404903 | biostudies-literature
| S-EPMC5431181 | biostudies-literature