Unknown

Dataset Information

0

Deep-tissue anatomical imaging of mice using carbon nanotube fluorophores in the second near-infrared window.


ABSTRACT: Fluorescent imaging in the second near-infrared window (NIR II, 1-1.4 ?m) holds much promise due to minimal autofluorescence and tissue scattering. Here, using well-functionalized biocompatible single-walled carbon nanotubes (SWNTs) as NIR II fluorescent imaging agents, we performed high-frame-rate video imaging of mice during intravenous injection of SWNTs and investigated the path of SWNTs through the mouse anatomy. We observed in real-time SWNT circulation through the lungs and kidneys several seconds postinjection, and spleen and liver at slightly later time points. Dynamic contrast-enhanced imaging through principal component analysis (PCA) was performed and found to greatly increase the anatomical resolution of organs as a function of time postinjection. Importantly, PCA was able to discriminate organs such as the pancreas, which could not be resolved from real-time raw images. Tissue phantom studies were performed to compare imaging in the NIR II region to the traditional NIR I biological transparency window (700-900 nm). Examination of the feature sizes of a common NIR I dye (indocyanine green) showed a more rapid loss of feature contrast and integrity with increasing feature depth as compared to SWNTs in the NIR II region. The effects of increased scattering in the NIR I versus NIR II region were confirmed by Monte Carlo simulation. In vivo fluorescence imaging in the NIR II region combined with PCA analysis may represent a powerful approach to high-resolution optical imaging through deep tissues, useful for a wide range of applications from biomedical research to disease diagnostics.

SUBMITTER: Welsher K 

PROVIDER: S-EPMC3107273 | biostudies-other | 2011 May

REPOSITORIES: biostudies-other

altmetric image

Publications

Deep-tissue anatomical imaging of mice using carbon nanotube fluorophores in the second near-infrared window.

Welsher Kevin K   Sherlock Sarah P SP   Dai Hongjie H  

Proceedings of the National Academy of Sciences of the United States of America 20110516 22


Fluorescent imaging in the second near-infrared window (NIR II, 1-1.4 μm) holds much promise due to minimal autofluorescence and tissue scattering. Here, using well-functionalized biocompatible single-walled carbon nanotubes (SWNTs) as NIR II fluorescent imaging agents, we performed high-frame-rate video imaging of mice during intravenous injection of SWNTs and investigated the path of SWNTs through the mouse anatomy. We observed in real-time SWNT circulation through the lungs and kidneys severa  ...[more]

Similar Datasets

| S-EPMC7594590 | biostudies-literature
| S-EPMC5679521 | biostudies-literature
| S-EPMC6137042 | biostudies-literature
| S-EPMC4063980 | biostudies-literature
| S-EPMC5062498 | biostudies-literature
| S-EPMC4585673 | biostudies-literature
| S-EPMC6506383 | biostudies-literature