Unknown

Dataset Information

0

Integral dose and radiation-induced secondary malignancies: comparison between stereotactic body radiation therapy and three-dimensional conformal radiotherapy.


ABSTRACT: The aim of the present paper is to compare the integral dose received by non-tumor tissue (NTID) in stereotactic body radiation therapy (SBRT) with modified LINAC with that received by three-dimensional conformal radiotherapy (3D-CRT), estimating possible correlations between NTID and radiation-induced secondary malignancy risk. Eight patients with intrathoracic lesions were treated with SBRT, 23 Gy × 1 fraction. All patients were then replanned for 3D-CRT, maintaining the same target coverage and applying a dose scheme of 2 Gy × 32 fractions. The dose equivalence between the different treatment modalities was achieved assuming ?/? = 10 Gy for tumor tissue and imposing the same biological effective dose (BED) on the target (BED = 76 Gy(10)). Total NTIDs for both techniques was calculated considering ?/? = 3 Gy for healthy tissue. Excess absolute cancer risk (EAR) was calculated for various organs using a mechanistic model that includes fractionation effects. A paired two-tailed Student t-test was performed to determine statistically significant differences between the data (p ? 0.05). Our study indicates that despite the fact that for all patients integral dose is higher for SBRT treatments than 3D-CRT (p = 0.002), secondary cancer risk associated to SBRT patients is significantly smaller than that calculated for 3D-CRT (p = 0.001). This suggests that integral dose is not a good estimator for quantifying cancer induction. Indeed, for the model and parameters used, hypofractionated radiotherapy has the potential for secondary cancer reduction. The development of reliable secondary cancer risk models seems to be a key issue in fractionated radiotherapy. Further assessments of integral doses received with 3D-CRT and other special techniques are also strongly encouraged.

SUBMITTER: D'Arienzo M 

PROVIDER: S-EPMC3524624 | biostudies-other | 2012 Nov

REPOSITORIES: biostudies-other

altmetric image

Publications

Integral dose and radiation-induced secondary malignancies: comparison between stereotactic body radiation therapy and three-dimensional conformal radiotherapy.

D'Arienzo Marco M   Masciullo Stefano G SG   de Sanctis Vitaliana V   Osti Mattia F MF   Chiacchiararelli Laura L   Enrici Riccardo M RM  

International journal of environmental research and public health 20121119 11


The aim of the present paper is to compare the integral dose received by non-tumor tissue (NTID) in stereotactic body radiation therapy (SBRT) with modified LINAC with that received by three-dimensional conformal radiotherapy (3D-CRT), estimating possible correlations between NTID and radiation-induced secondary malignancy risk. Eight patients with intrathoracic lesions were treated with SBRT, 23 Gy × 1 fraction. All patients were then replanned for 3D-CRT, maintaining the same target coverage a  ...[more]

Similar Datasets

| S-EPMC6119304 | biostudies-literature
| S-EPMC5201122 | biostudies-literature
| S-EPMC5714543 | biostudies-literature
| S-EPMC8058022 | biostudies-literature
| S-EPMC5874664 | biostudies-literature
| S-EPMC5718687 | biostudies-other
| S-EPMC7807546 | biostudies-literature
| S-EPMC7761604 | biostudies-literature
| S-EPMC11236383 | biostudies-literature
| S-EPMC7080561 | biostudies-literature