Feasibility of conjunctival hemodynamic measurements in rabbits: reproducibility, validity, and response to acute hypotension.


ABSTRACT: OBJECTIVE:To evaluate the feasibility of conjunctival hemodynamic measurements based on assessment of reproducibility, validity, and response to acute hypotension. METHODS:Image sequences of the conjunctival microvasculature of rabbits were captured using a slit lamp biomicroscope under a steady-state condition, after topical administration of phenylephrine, and after intravenous administration of esmolol. Venous hemodynamic parameters (diameter, blood velocity, blood flow, and wall shear stress) were derived. RESULTS:Conjunctival venous diameters ranged from 9 to 34 ?m and blood velocities ranged from 0.08 to 0.95 mm/s. Coefficients of variation of venous diameter and blood velocity measurements were, on average, 6% and 14%, respectively. Automated and manual measurements of venous diameter and velocity were highly correlated (R = 0.97; p < 0.001; n = 16). With phenylephrine administration, diameter and velocity were reduced by 21% and 69%, respectively. Following esmolol administration, blood pressure was reduced with a concomitant decrease in velocity, followed by recovery to baseline. Venous blood velocity, flow, and WSS were correlated with blood pressure (R ? 0.52; p ? 0.01). CONCLUSIONS:The feasibility of quantifying alterations in microvascular hemodynamics in the bulbar conjunctiva was established. The method is of potential value in evaluating microcirculatory hemodynamics related to cardiovascular function.

SUBMITTER: Gaynes B 

PROVIDER: S-EPMC3648337 | biostudies-other | 2012 Aug

REPOSITORIES: biostudies-other

altmetric image

Publications

Feasibility of conjunctival hemodynamic measurements in rabbits: reproducibility, validity, and response to acute hypotension.

Gaynes Bruce B   Teng Pang-Yu PY   Wanek Justin J   Shahidi Mahnaz M  

Microcirculation (New York, N.Y. : 1994) 20120801 6


<h4>Objective</h4>To evaluate the feasibility of conjunctival hemodynamic measurements based on assessment of reproducibility, validity, and response to acute hypotension.<h4>Methods</h4>Image sequences of the conjunctival microvasculature of rabbits were captured using a slit lamp biomicroscope under a steady-state condition, after topical administration of phenylephrine, and after intravenous administration of esmolol. Venous hemodynamic parameters (diameter, blood velocity, blood flow, and wa  ...[more]

Similar Datasets

| S-EPMC6068938 | biostudies-literature
| S-EPMC8031559 | biostudies-literature
| S-EPMC9920913 | biostudies-literature
| S-EPMC7564383 | biostudies-literature
| S-EPMC10138748 | biostudies-literature
| S-EPMC7592795 | biostudies-literature
| S-EPMC6206914 | biostudies-literature
| S-EPMC3205089 | biostudies-literature
| S-EPMC10092202 | biostudies-literature
| S-EPMC7694267 | biostudies-literature