Retention of the Boston keratoprosthesis type 1: multicenter study results.


ABSTRACT: To report the retention rate of the Boston keratoprosthesis type 1 and to identify risk factors for keratoprosthesis loss.Cohort study.A total of 300 eyes of 300 patients who underwent implantation of the Boston keratoprosthesis type I device between January 2003 and July 2008 by 19 surgeons at 18 medical centers.Forms reporting preoperative, intraoperative, and postoperative parameters were prospectively collected and subsequently analyzed at a central data collection site.Keratoprosthesis retention.A total cumulative number of 422 life-years of device implantation are included in this analysis. The average duration of follow-up was 17.1 ± 14.8 months, with a range of 1 week to >6.1 years. Ninety-three percent of the 300 Boston keratoprosthesis implants were retained at their last follow-up, corresponding to a retention time of 396 patient-years or 1.42 years/keratoprosthesis. The probability of retention after 1 year and 2 years was 94% and 89%, respectively. During the study period, 21 (7%) eyes failed to retain the device; the reasons for keratoprosthesis loss include sterile keratolysis (9), fungal infections (8), dense retroprosthetic membranes (3), and bacterial endophthalmitis (1). Multivariate analysis demonstrated 3 independent risk factors for keratoprosthesis loss: autoimmune cause (hazard ratio [HR], 11.94; 95% confidence interval [CI], 3.31-43.11), ocular surface exposure requiring a concomitant tarsorrhaphy (HR, 3.43; 95% CI, 1.05-11.22), and number of prior failed penetrating keratoplasties (HR, 1.64; 95% CI, 1.18-2.28).The Boston keratoprosthesis type 1 seems to be a viable option for eyes that are not candidates for penetrating keratoplasty (PK). Ocular surface disease due to an autoimmune cause demonstrated the lowest retention rate.The author(s) have no proprietary or commercial interest in any materials discussed in this article.

SUBMITTER: Ciolino JB 

PROVIDER: S-EPMC3674188 | biostudies-other | 2013 Jun

REPOSITORIES: biostudies-other

altmetric image

Publications

Retention of the Boston keratoprosthesis type 1: multicenter study results.

Ciolino Joseph B JB   Belin Michael W MW   Todani Amit A   Al-Arfaj Khalid K   Rudnisky Christopher J CJ  

Ophthalmology 20130315 6


<h4>Objective</h4>To report the retention rate of the Boston keratoprosthesis type 1 and to identify risk factors for keratoprosthesis loss.<h4>Design</h4>Cohort study.<h4>Participants</h4>A total of 300 eyes of 300 patients who underwent implantation of the Boston keratoprosthesis type I device between January 2003 and July 2008 by 19 surgeons at 18 medical centers.<h4>Methods</h4>Forms reporting preoperative, intraoperative, and postoperative parameters were prospectively collected and subsequ  ...[more]

Similar Datasets

| S-EPMC8561078 | biostudies-literature
| S-EPMC5544178 | biostudies-literature
| S-EPMC3151563 | biostudies-literature
| S-EPMC3178310 | biostudies-other
| S-EPMC3298984 | biostudies-other
| S-EPMC6598731 | biostudies-literature
| S-EPMC8054627 | biostudies-literature
| S-EPMC6104558 | biostudies-literature
| S-EPMC5997695 | biostudies-other
| S-EPMC5800684 | biostudies-other