Will a quadruple multiplexed point-of-care screening strategy for HIV-related co-infections be feasible and impact detection of new co-infections in at-risk populations? Results from cross-sectional studies.


ABSTRACT: OBJECTIVES:Multiplexed point-of-care (POC) devices can rapidly screen for HIV-related co-infections (eg, hepatitis C (HCV), hepatitis B (HBV), syphilis) in one patient visit, but global evidence for this approach remains limited. This study aimed to evaluate a multiplex POC testing strategy to expedite screening for HIV-related co-infections in at-risk populations. METHODS:A multiplex strategy was developed with two subsequent versions of an investigational device Miriad. It was evaluated in two non-comparable settings and populations in two countries for feasibility of conduct, detection of new infections, preference and accuracy. Version 1 was evaluated in 375 sexually transmitted disease clinic attendees in Mumbai, India; version 2 was evaluated in 119 injection drug users in Montreal, Canada. RESULTS:Feasibility (completion rate) of the multiplex strategy was high (86.1% Mumbai; 92.4% Montreal). A total of 170 new infections were detected in Mumbai (56 HIV, 75 HBV, 37 syphilis, 2 HCV) versus 2 in Montreal. Preference was 60% in Mumbai and 97% in Montreal. Miriad version 1 specificities were high: HIV 99.7% (98.3% to 100%), HBV 99.3% (97.6% to 99.9%), HCV 99.7% (98.5% to 99.9%), syphilis 85.2% (80.9% to 88.8%); sensitivities were as follows: HIV 100% (94.8% to 100%), HBV 13.3% (6.6% to 23.2%), HCV 50% (1.3% to 98.7%), syphilis 86.1% (70.5% to 95.3%). With version 2, specificities improved: HIV 100% (97.2% to 100%), HBV 100% (97.3% to 100%), HCV 85.3% (73.8% to 93.0%), syphilis 98.1% (93.3% to 99.8%); sensitivities were: HIV 100% (47.3% to 100%), HCV 80.4% (66.1% to 90.6%), syphilis 100% (22.4% to 100%). CONCLUSIONS:A quad multiplex POC strategy for HIV and co-infections was feasible to operationalise and preferred by patients in both settings. Many new infections were identified in Mumbai and accuracy improved with version 2 of the assay. Such a strategy will help expedite screening for co-infections, particularly where baseline screening is low. These findings are valuable to practitioners, researchers, policymakers and funders involved in initiatives for all four diseases with implications for scale-up.

SUBMITTER: Pai NP 

PROVIDER: S-EPMC4267080 | biostudies-other | 2014 Dec

REPOSITORIES: biostudies-other

altmetric image

Publications

Will a quadruple multiplexed point-of-care screening strategy for HIV-related co-infections be feasible and impact detection of new co-infections in at-risk populations? Results from cross-sectional studies.

Pai Nitika Pant NP   Dhurat Rachita R   Potter Martin M   Behlim Tarannum T   Landry Geneviève G   Vadnais Caroline C   Rodrigues Camilla C   Joseph Lawrence L   Shetty Anjali A  

BMJ open 20141215 12


<h4>Objectives</h4>Multiplexed point-of-care (POC) devices can rapidly screen for HIV-related co-infections (eg, hepatitis C (HCV), hepatitis B (HBV), syphilis) in one patient visit, but global evidence for this approach remains limited. This study aimed to evaluate a multiplex POC testing strategy to expedite screening for HIV-related co-infections in at-risk populations.<h4>Methods</h4>A multiplex strategy was developed with two subsequent versions of an investigational device Miriad. It was e  ...[more]

Similar Datasets

| S-EPMC9176175 | biostudies-literature
| S-EPMC6580765 | biostudies-literature
| S-EPMC5538621 | biostudies-literature
| S-EPMC4375962 | biostudies-literature
| S-EPMC4120374 | biostudies-other
| S-EPMC3690865 | biostudies-other
| S-EPMC5217126 | biostudies-literature
| S-EPMC7283491 | biostudies-literature
| S-EPMC4266136 | biostudies-literature
| S-EPMC9250411 | biostudies-literature