Unknown

Dataset Information

0

Assessment of metabolic fluxes in the mouse brain in vivo using 1H-[13C] NMR spectroscopy at 14.1 Tesla.


ABSTRACT: (13)C magnetic resonance spectroscopy (MRS) combined with the administration of (13)C labeled substrates uniquely allows to measure metabolic fluxes in vivo in the brain of humans and rats. The extension to mouse models may provide exclusive prospect for the investigation of models of human diseases. In the present study, the short-echo-time (TE) full-sensitivity (1)H-[(13)C] MRS sequence combined with high magnetic field (14.1 T) and infusion of [U-(13)C6] glucose was used to enhance the experimental sensitivity in vivo in the mouse brain and the (13)C turnover curves of glutamate C4, glutamine C4, glutamate+glutamine C3, aspartate C2, lactate C3, alanine C3, ?-aminobutyric acid C2, C3 and C4 were obtained. A one-compartment model was used to fit (13)C turnover curves and resulted in values of metabolic fluxes including the tricarboxylic acid (TCA) cycle flux VTCA (1.05 ± 0.04 ?mol/g per minute), the exchange flux between 2-oxoglutarate and glutamate Vx (0.48 ± 0.02 ?mol/g per minute), the glutamate-glutamine exchange rate V(gln) (0.20 ± 0.02 ?mol/g per minute), the pyruvate dilution factor K(dil) (0.82 ± 0.01), and the ratio for the lactate conversion rate and the alanine conversion rate V(Lac)/V(Ala) (10 ± 2). This study opens the prospect of studying transgenic mouse models of brain pathologies.

SUBMITTER: Xin L 

PROVIDER: S-EPMC4420852 | biostudies-other | 2015 May

REPOSITORIES: biostudies-other

altmetric image

Publications

Assessment of metabolic fluxes in the mouse brain in vivo using 1H-[13C] NMR spectroscopy at 14.1 Tesla.

Xin Lijing L   Lanz Bernard B   Lei Hongxia H   Gruetter Rolf R  

Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism 20150121 5


(13)C magnetic resonance spectroscopy (MRS) combined with the administration of (13)C labeled substrates uniquely allows to measure metabolic fluxes in vivo in the brain of humans and rats. The extension to mouse models may provide exclusive prospect for the investigation of models of human diseases. In the present study, the short-echo-time (TE) full-sensitivity (1)H-[(13)C] MRS sequence combined with high magnetic field (14.1 T) and infusion of [U-(13)C6] glucose was used to enhance the experi  ...[more]

Similar Datasets

| S-EPMC7074231 | biostudies-literature
| 2183890 | ecrin-mdr-crc
| S-EPMC6040279 | biostudies-literature
| S-EPMC3694136 | biostudies-other
| S-EPMC1513184 | biostudies-other
| S-EPMC2879471 | biostudies-literature
| S-EPMC4523238 | biostudies-literature
| S-EPMC2479603 | biostudies-literature
| S-EPMC3947269 | biostudies-literature
| S-EPMC6168901 | biostudies-other