Unknown

Dataset Information

0

Real-time integrated photoacoustic and ultrasound (PAUS) imaging system to guide interventional procedures: ex vivo study.


ABSTRACT: Because of depth-dependent light attenuation, bulky, low-repetition-rate lasers are usually used in most photoacoustic (PA) systems to provide sufficient pulse energies to image at depth within the body. However, integrating these lasers with real-time clinical ultrasound (US) scanners has been problematic because of their size and cost. In this paper, an integrated PA/US (PAUS) imaging system is presented operating at frame rates >30 Hz. By employing a portable, low-cost, low-pulse-energy (~2 mJ/pulse), high-repetition-rate (~1 kHz), 1053-nm laser, and a rotating galvo-mirror system enabling rapid laser beam scanning over the imaging area, the approach is demonstrated for potential applications requiring a few centimeters of penetration. In particular, we demonstrate here real-time (30 Hz frame rate) imaging (by combining multiple single-shot sub-images covering the scan region) of an 18-gauge needle inserted into a piece of chicken breast with subsequent delivery of an absorptive agent at more than 1-cm depth to mimic PAUS guidance of an interventional procedure. A signal-to-noise ratio of more than 35 dB is obtained for the needle in an imaging area 2.8 × 2.8 cm (depth × lateral). Higher frame rate operation is envisioned with an optimized scanning scheme.

SUBMITTER: Wei CW 

PROVIDER: S-EPMC4610852 | biostudies-other | 2015 Feb

REPOSITORIES: biostudies-other

altmetric image

Publications

Real-time integrated photoacoustic and ultrasound (PAUS) imaging system to guide interventional procedures: ex vivo study.

Wei Chen-Wei CW   Nguyen Thu-Mai TM   Xia Jinjun J   Arnal Bastien B   Wong Emily Y EY   Pelivanov Ivan M IM   O'Donnell Matthew M  

IEEE transactions on ultrasonics, ferroelectrics, and frequency control 20150201 2


Because of depth-dependent light attenuation, bulky, low-repetition-rate lasers are usually used in most photoacoustic (PA) systems to provide sufficient pulse energies to image at depth within the body. However, integrating these lasers with real-time clinical ultrasound (US) scanners has been problematic because of their size and cost. In this paper, an integrated PA/US (PAUS) imaging system is presented operating at frame rates >30 Hz. By employing a portable, low-cost, low-pulse-energy (~2 m  ...[more]

Similar Datasets

| S-EPMC5982119 | biostudies-literature
| S-EPMC3123396 | biostudies-literature
| S-EPMC5059665 | biostudies-literature
| S-EPMC6203764 | biostudies-literature
| S-EPMC6953120 | biostudies-literature
| S-EPMC5781326 | biostudies-other
| S-EPMC4392510 | biostudies-literature
| S-EPMC7969124 | biostudies-literature
| S-EPMC4113013 | biostudies-literature
| S-EPMC5217184 | biostudies-literature