Comparison of commercial nanoliquid chromatography columns for fast, targeted mass spectrometry-based proteomics.


ABSTRACT: We compared four commonly used, commercially available reverse phase nanoLC columns for identification/determination of Wnt/?-catenin-related pathway proteins.The columns were: Chromolith® (silica monolith; Merke Millipore, MA, USA), PepMap™ (porous particles; Thermo Fisher Scientific, MA, USA), Accucore™ (solid core particles; Thermo Fisher Scientific) and PepSwift™ (organic monolith; Thermo Fisher Scientific).The peak capacity of the columns varied from 100 (Pepswift) to 190 (Accucore) (for 30 min gradients). All columns enabled identification/detection of GSK3? and ?-catenin in the complex samples. However, even the columns with higher peak capacities could not enable detection of the somewhat less abundant proteins AXIN2 and TNKS2. The monoliths were more prone to retention time instability when sample complexity increased.We find that commercial nanoLC columns, although featuring different morphologies and peak capacities, provided surprisingly few practical differences for relatively fast, targeted determination of proteins.

SUBMITTER: Vehus T 

PROVIDER: S-EPMC5137844 | biostudies-other | 2016 Jun

REPOSITORIES: biostudies-other

altmetric image

Publications

Comparison of commercial nanoliquid chromatography columns for fast, targeted mass spectrometry-based proteomics.

Vehus Tore T   Seterdal Kristina Erikstad KE   Krauss Stefan S   Lundanes Elsa E   Wilson Steven R SR  

Future science OA 20160316 2


<h4>Aim</h4>We compared four commonly used, commercially available reverse phase nanoLC columns for identification/determination of Wnt/β-catenin-related pathway proteins.<h4>Materials & methods</h4>The columns were: Chromolith<sup>®</sup> (silica monolith; Merke Millipore, MA, USA), PepMap™ (porous particles; Thermo Fisher Scientific, MA, USA), Accucore™ (solid core particles; Thermo Fisher Scientific) and PepSwift™ (organic monolith; Thermo Fisher Scientific).<h4>Results</h4>The peak capacity  ...[more]

Similar Datasets

| S-EPMC7279521 | biostudies-literature
| S-EPMC8374269 | biostudies-literature
| S-EPMC4947469 | biostudies-literature
| S-EPMC9048214 | biostudies-literature
| S-EPMC3254673 | biostudies-literature
| S-EPMC2830836 | biostudies-other
| EGAC00001002236 | EGA
| S-EPMC7321193 | biostudies-literature
| S-EPMC7059694 | biostudies-literature
| S-EPMC5557563 | biostudies-literature