Technical Limitations of the C1q Single-Antigen Bead Assay to Detect Complement Binding HLA-Specific Antibodies.


ABSTRACT: Solid-phase assays to distinguish complement binding from noncomplement binding HLA-specific antibodies have been introduced, but technical limitations may compromise their interpretation. We have examined the extent to which C1q-binding to HLA-class I single-antigen beads (SAB) is influenced by denatured HLA on SAB, antibody titre, and complement interference that causes a misleading low assessment of HLA-specific antibody levels.Sera from 25 highly sensitized patients were tested using Luminex IgG-SAB and C1q-SAB assays. Sera were tested undiluted, at 1:20 dilution to detect high-level IgG, and after ethylene diamine tetraacetic acid treatment to obviate complement interference. Conformational HLA and denatured HLA protein levels on SAB were determined using W6/32 and HC-10 monoclonal antibodies, respectively. Denatured HLA was expressed as HC-10 binding to untreated SAB as a percentage of maximal binding to acid-treated SAB.For undiluted sera, Luminex mean fluorescence intensity (MFI) values for IgG-SAB and C1q-SAB correlated poorly (r = 0.42). ethylene diamine tetraacetic acid and serum dilution improved the correlation (r = 0.57 and 0.77, respectively). Increasing levels of denatured HLA interfered with the detection of C1q binding. Consequently, the correlation between IgG-SAB MFI and C1q-SAB MFI was lowest using undiluted sera and SAB with greater than 30% denatured HLA (r = 0.40) and highest using diluted sera and SAB with 30% or less denatured HLA (r = 0.86).Antibody level, complement interference, and denatured HLA class I on SAB may all affect the clinical interpretation of the C1q-SAB assay. The C1q-SAB assay represents a substantial additional cost for routine clinical use, and we question its justification given the potential uncertainty about its interpretation.

SUBMITTER: Taylor CJ 

PROVIDER: S-EPMC5457814 | biostudies-other | 2017 Jun

REPOSITORIES: biostudies-other

altmetric image

Publications

Technical Limitations of the C1q Single-Antigen Bead Assay to Detect Complement Binding HLA-Specific Antibodies.

Taylor Craig J CJ   Kosmoliaptsis Vasilis V   Martin Jessie J   Knighton Graham G   Mallon Dermot D   Bradley J Andrew JA   Peacock Sarah S  

Transplantation 20170601 6


<h4>Background</h4>Solid-phase assays to distinguish complement binding from noncomplement binding HLA-specific antibodies have been introduced, but technical limitations may compromise their interpretation. We have examined the extent to which C1q-binding to HLA-class I single-antigen beads (SAB) is influenced by denatured HLA on SAB, antibody titre, and complement interference that causes a misleading low assessment of HLA-specific antibody levels.<h4>Methods</h4>Sera from 25 highly sensitized  ...[more]

Similar Datasets

| S-EPMC6206241 | biostudies-literature
| S-EPMC6981440 | biostudies-literature
| S-EPMC4820514 | biostudies-literature
| S-EPMC7381122 | biostudies-literature
| S-EPMC4404182 | biostudies-literature
| S-EPMC5844480 | biostudies-literature
| S-EPMC6235372 | biostudies-literature
| S-EPMC6817106 | biostudies-literature
| S-EPMC7829346 | biostudies-literature
| S-EPMC7267003 | biostudies-literature