Unknown

Dataset Information

0

Aqueous Angiography in Living Nonhuman Primates Shows Segmental, Pulsatile, and Dynamic Angiographic Aqueous Humor Outflow.


ABSTRACT: To evaluate the feasibility of safely performing aqueous angiography in intact eyes of living nonhuman primates (NHPs) for evaluating aqueous humor outflow and segmental patterns.Cross-sectional, observational study.Six nonhuman primates.Aqueous angiography was performed in 6 nonhuman primates. After anesthesia, an anterior chamber (AC) maintainer was placed through a temporal 1-mm side-port wound. Indocyanine green (ICG; 0.4%) or 2.5% fluorescein was introduced (individually or in sequence) into the eye with a gravity-driven constant-pressure system. Aqueous angiography images were obtained with a Spectralis HRA+OCT (Heidelberg Engineering GmbH, Heidelberg, Germany) suspended over the NHP eye using a custom-designed surgical boom arm. Concurrent anterior segment optical coherence tomography (OCT) was performed on distally angiographically positive and negative regions.Angiographic patterns described by location, time-course, choice of tracer, and anterior-segment OCT.Aqueous angiography in the living NHP eye demonstrated mostly stable angiographic patterns. With multimodal imaging, angiographically positive signal co-localized with episcleral veins as identified by infrared imaging and intrascleral lumens, as demonstrated by anterior segment OCT. Sequential aqueous angiography in individual eyes with ICG followed by fluorescein showed similar angiographic patterns. A pulsatile nature of aqueous angiographic outflow was sometimes observed. Aqueous angiographic patterns could also dynamically change. In some instances, positive angiographic flow suddenly arose in regions previously without an angiographic signal. Alternatively, an angiographic signal could suddenly disappear from regions in which an angiographic signal was initially documented.Aqueous angiography in living NHPs demonstrated segmental and pulsatile patterns with a newly described ability to dynamically shift. These characteristics further the understanding of live aqueous humor outflow biology and may be useful in improving glaucoma surgeries aimed at trabecular meshwork bypass.

SUBMITTER: Huang AS 

PROVIDER: S-EPMC5484000 | biostudies-other | 2017 Jun

REPOSITORIES: biostudies-other

altmetric image

Publications

Aqueous Angiography in Living Nonhuman Primates Shows Segmental, Pulsatile, and Dynamic Angiographic Aqueous Humor Outflow.

Huang Alex S AS   Li Meng M   Yang Diya D   Wang Huaizhou H   Wang Ningli N   Weinreb Robert N RN  

Ophthalmology 20170223 6


<h4>Purpose</h4>To evaluate the feasibility of safely performing aqueous angiography in intact eyes of living nonhuman primates (NHPs) for evaluating aqueous humor outflow and segmental patterns.<h4>Design</h4>Cross-sectional, observational study.<h4>Subjects</h4>Six nonhuman primates.<h4>Methods</h4>Aqueous angiography was performed in 6 nonhuman primates. After anesthesia, an anterior chamber (AC) maintainer was placed through a temporal 1-mm side-port wound. Indocyanine green (ICG; 0.4%) or 2  ...[more]

Similar Datasets

| S-EPMC4725949 | biostudies-literature
| S-EPMC5017267 | biostudies-literature
| S-EPMC7028348 | biostudies-literature
2003-07-16 | GSE492 | GEO
| S-EPMC7990028 | biostudies-literature
| S-EPMC4801333 | biostudies-literature
| S-EPMC7829208 | biostudies-literature
| S-EPMC6548641 | biostudies-literature
2021-08-06 | GSE168200 | GEO
| S-EPMC8523664 | biostudies-literature