Trabecular deformations during screw pull-out: a micro-CT study of lapine bone.


ABSTRACT: The mechanical fixation of endosseous implants, such as screws, in trabecular bone is challenging because of the complex porous microstructure. Development of new screw designs to improve fracture fixation, especially in high-porosity osteoporotic bone, requires a profound understanding of how the structural system implant/trabeculae interacts when it is subjected to mechanical load. In this study, pull-out tests of screw implants were performed. Screws were first inserted into the trabecular bone of rabbit femurs and then pulled out from the bone inside a computational tomography scanner. The tests were interrupted at certain load steps to acquire 3D images. The images were then analysed with a digital volume correlation technique to estimate deformation and strain fields inside the bone during the tests. The results indicate that the highest shear strains are concentrated between the inner and outer thread diameter, whereas compressive strains are found at larger distances from the screw. Tensile strains were somewhat smaller. Strain concentrations and the location of trabecular failures provide experimental information that could be used in the development of new screw designs and/or to validate numerical simulations.

SUBMITTER: Joffre T 

PROVIDER: S-EPMC5511599 | biostudies-other | 2017 Aug

REPOSITORIES: biostudies-other

altmetric image

Publications

Trabecular deformations during screw pull-out: a micro-CT study of lapine bone.

Joffre Thomas T   Isaksson Per P   Procter Philip P   Persson Cecilia C  

Biomechanics and modeling in mechanobiology 20170306 4


The mechanical fixation of endosseous implants, such as screws, in trabecular bone is challenging because of the complex porous microstructure. Development of new screw designs to improve fracture fixation, especially in high-porosity osteoporotic bone, requires a profound understanding of how the structural system implant/trabeculae interacts when it is subjected to mechanical load. In this study, pull-out tests of screw implants were performed. Screws were first inserted into the trabecular bo  ...[more]

Similar Datasets

| S-EPMC6175131 | biostudies-literature
| S-EPMC4398446 | biostudies-literature
| S-EPMC3922263 | biostudies-other
| S-EPMC10588705 | biostudies-literature
| S-EPMC5074884 | biostudies-literature
| S-EPMC2295271 | biostudies-literature
| S-EPMC3131277 | biostudies-literature
| S-EPMC10547782 | biostudies-literature
| S-EPMC9376842 | biostudies-literature
| S-EPMC6213059 | biostudies-literature