Quantitative and clinical impact of MRI-based attenuation correction methods in [18F]FDG evaluation of dementia.


ABSTRACT: BACKGROUND:Positron emission tomography/magnetic resonance imaging (PET/MRI) is a promising diagnostic imaging tool for the diagnosis of dementia, as PET can add complementary information to the routine imaging examination with MRI. The purpose of this study was to evaluate the influence of MRI-based attenuation correction (MRAC) on diagnostic assessment of dementia with [18F]FDG PET. Quantitative differences in both [18F]FDG uptake and z-scores were calculated for three clinically available (DixonNoBone, DixonBone, UTE) and two research MRAC methods (UCL, DeepUTE) compared to CT-based AC (CTAC). Furthermore, diagnoses based on visual evaluations were made by three nuclear medicine physicians and one neuroradiologist (PETCT, PETDeepUTE, PETDixonBone, PETUTE, PETCT + MRI, PETDixonBone + MRI). In addition, pons and cerebellum were compared as reference regions for normalization. RESULTS:The mean absolute difference in z-scores were smallest between MRAC and CTAC with cerebellum as reference region: 0.15 ± 0.11 σ (DeepUTE), 0.15 ± 0.12 σ (UCL), 0.23 ± 0.20 σ (DixonBone), 0.32 ± 0.28 σ (DixonNoBone), and 0.54 ± 0.40 σ (UTE). In the visual evaluation, the diagnoses agreed with PETCT in 74% (PETDeepUTE), 67% (PETDixonBone), and 70% (PETUTE) of the patients, while PETCT + MRI agreed with PETDixonBone + MRI in 89% of the patients. CONCLUSION:The MRAC research methods performed close to that of CTAC in the quantitative evaluation of [18F]FDG uptake and z-scores. Among the clinically implemented MRAC methods, DixonBone should be preferred for diagnostic assessment of dementia with [18F]FDG PET/MRI. However, as artifacts occur in DixonBone attenuation maps, they must be visually inspected to assure proper quantification.

SUBMITTER: Oen SK 

PROVIDER: S-EPMC6708519 | biostudies-other | 2019 Aug

REPOSITORIES: biostudies-other

altmetric image

Publications

Quantitative and clinical impact of MRI-based attenuation correction methods in [<sup>18</sup>F]FDG evaluation of dementia.

Øen Silje Kjærnes SK   Keil Thomas Morten TM   Berntsen Erik Magnus EM   Aanerud Joel Fredrik JF   Schwarzlmüller Thomas T   Ladefoged Claes Nøhr CN   Karlberg Anna Maria AM   Eikenes Live L  

EJNMMI research 20190824 1


<h4>Background</h4>Positron emission tomography/magnetic resonance imaging (PET/MRI) is a promising diagnostic imaging tool for the diagnosis of dementia, as PET can add complementary information to the routine imaging examination with MRI. The purpose of this study was to evaluate the influence of MRI-based attenuation correction (MRAC) on diagnostic assessment of dementia with [<sup>18</sup>F]FDG PET. Quantitative differences in both [<sup>18</sup>F]FDG uptake and z-scores were calculated for  ...[more]

Similar Datasets

| S-EPMC6433217 | biostudies-literature
| S-EPMC6230542 | biostudies-other
| S-EPMC6779234 | biostudies-literature
| S-EPMC7246235 | biostudies-literature
| S-EPMC6449185 | biostudies-literature
| S-EPMC8195345 | biostudies-literature
| S-EPMC6261857 | biostudies-literature
| S-EPMC9293017 | biostudies-literature
| S-EPMC6681691 | biostudies-literature
| S-EPMC6290790 | biostudies-literature