Multiparametric radiobiological assays show that variation of X-ray energy strongly impacts relative biological effectiveness: comparison between 220 kV and 4 MV.


ABSTRACT: Based on classic clonogenic assay, it is accepted by the scientific community that, whatever the energy, the relative biological effectiveness of X-rays is equal to 1. However, although X-ray beams are widely used in diagnosis, interventional medicine and radiotherapy, comparisons of their energies are scarce. We therefore assessed in vitro the effects of low- and high-energy X-rays using Human umbilical vein endothelial cells (HUVECs) by performing clonogenic assay, measuring viability/mortality, counting γ-H2AX foci, studying cell proliferation and cellular senescence by flow cytometry and by performing gene analysis on custom arrays. Taken together, excepted for γ-H2AX foci counts, these experiments systematically show more adverse effects of high energy X-rays, while the relative biological effectiveness of photons is around 1, whatever the quality of the X-ray beam. These results strongly suggest that multiparametric analysis should be considered in support of clonogenic assay.

SUBMITTER: Paget V 

PROVIDER: S-EPMC6778087 | biostudies-other | 2019 Oct

REPOSITORIES: biostudies-other

altmetric image

Publications

Multiparametric radiobiological assays show that variation of X-ray energy strongly impacts relative biological effectiveness: comparison between 220 kV and 4 MV.

Paget Vincent V   Ben Kacem Mariam M   Dos Santos Morgane M   Benadjaoud Mohamed A MA   Soysouvanh Frédéric F   Buard Valérie V   Georges Tarlet T   Vaurijoux Aurélie A   Gruel Gaëtan G   François Agnès A   Guipaud Olivier O   Milliat Fabien F  

Scientific reports 20191004 1


Based on classic clonogenic assay, it is accepted by the scientific community that, whatever the energy, the relative biological effectiveness of X-rays is equal to 1. However, although X-ray beams are widely used in diagnosis, interventional medicine and radiotherapy, comparisons of their energies are scarce. We therefore assessed in vitro the effects of low- and high-energy X-rays using Human umbilical vein endothelial cells (HUVECs) by performing clonogenic assay, measuring viability/mortalit  ...[more]

Similar Datasets

| S-EPMC7184727 | biostudies-literature
| S-EPMC4831078 | biostudies-literature
| S-EPMC5690018 | biostudies-literature
| S-EPMC3608045 | biostudies-other
| S-EPMC4494349 | biostudies-literature
| S-EPMC5530664 | biostudies-literature
| S-EPMC6637429 | biostudies-literature
| S-EPMC3313672 | biostudies-literature
2014-06-04 | GSE58172 | GEO
| S-EPMC5916785 | biostudies-literature