Unknown

Dataset Information

0

Development of a Portable Detection Method for Enteric Viruses from Ambient Air and Its Application to a Wastewater Treatment Plant.


ABSTRACT: The ambient air from wastewater treatment plants has been considered as a potential source of pathogenic microorganisms to cause an occupational risk for the workers of the plants. Existing detection methods for enteric viruses from the air using a liquid as the collection medium therefore require special care to handle on-site. Knowledge accumulation on airborne virus risks from wastewater has been hindered by a lack of portable and handy collection methods. Enteric viruses are prevalent at high concentrations in wastewater; thus, the surrounding air may also be a potential source of viral transmission. We developed a portable collection and detection method for enteric viruses from ambient air and applied it to an actual wastewater treatment plant in Japan. Materials of the collection medium and eluting methods were optimized for real-time polymerase chain reaction-based virus quantification. The method uses a 4 L/min active air sampler, which is capable of testing 0.7-1.6 m3 air after 3-7 h sampling with a detection limit of 102 copies/m3 air in the field. Among 16 samples collected at five to seven locations in three sampling trials (November 2007-January 2008), 56% (9/16) samples were positive for norovirus (NV) GII, with the highest concentration of 3.2 × 103 copies/m3 air observed at the sampling point near a grit chamber. Adenoviruses (4/16), NV GI (6/16), FRNA bacteriophages GIII (3/16), and enteroviruses (3/16) were also detected but at lower concentrations. The virus concentration in the air was associated with that of the wastewater at each process. The results imply that the air from the sewer pipes or treatment process is contaminated by enteric viruses and thus special attention is needed to avoid accidental ingestion of viruses via air.

SUBMITTER: Matsubara K 

PROVIDER: S-EPMC6789845 | biostudies-other | 2019 Aug

REPOSITORIES: biostudies-other

altmetric image

Publications

Development of a Portable Detection Method for Enteric Viruses from Ambient Air and Its Application to a Wastewater Treatment Plant.

Matsubara Koichi K   Katayama Hiroyuki H  

Pathogens (Basel, Switzerland) 20190824 3


The ambient air from wastewater treatment plants has been considered as a potential source of pathogenic microorganisms to cause an occupational risk for the workers of the plants. Existing detection methods for enteric viruses from the air using a liquid as the collection medium therefore require special care to handle on-site. Knowledge accumulation on airborne virus risks from wastewater has been hindered by a lack of portable and handy collection methods. Enteric viruses are prevalent at hig  ...[more]

Similar Datasets

| S-EPMC7090394 | biostudies-literature
2008-04-18 | GSE11195 | GEO
2008-04-18 | E-GEOD-11195 | biostudies-arrayexpress
| S-EPMC6769854 | biostudies-literature
| S-EPMC4542245 | biostudies-literature
| S-EPMC7086948 | biostudies-literature
| S-EPMC7368910 | biostudies-literature
| S-EPMC404457 | biostudies-literature
| S-EPMC7086814 | biostudies-literature
| S-EPMC6444421 | biostudies-literature