Metabolomics

Dataset Information

0

MetaboKit: a comprehensive data extraction tool for untargeted metabolomics (Standard mixture assay)


ABSTRACT:

We have developed MetaboKit, a comprehensive software package for compound identification and relative quantification in mass spectrometry-based untargeted metabolomics analysis. In data dependent acquisition (DDA) analysis, MetaboKit constructs a customized spectral library with compound identities from reference spectral libraries, adducts, dimers, in-source fragments (ISF), MS/MS fragmentation spectra, and more importantly the retention time information unique to the chromatography system used in the experiment. Using the customized library, the software performs targeted peak integration for precursor ions in DDA analysis and for precursor and product ions in data independent acquisition (DIA) analysis. With its stringent identification algorithm requiring matches by both MS and MS/MS data, MetaboKit provides identification results with significantly greater specificity than the competing software packages without loss in sensitivity. The proposed MS/MS-based screening of ISFs also reduces the chance of unverifiable identification of ISFs considerably. MetaboKit's quantification module produced peak area values highly correlated with known concentrations in a DIA analysis of the metabolite standards at both MS1 and MS2 levels. Moreover, the analysis of Cdk1Liv-/- mouse livers showed that MetaboKit can identify a wide range of lipid species and their ISFs, and quantitatively reconstitute the well-characterized fatty liver phenotype in these mice. In DIA data, the MS1-level and MS2-level peak area data produced similar fold change estimates in the differential abundance analysis, and the MS2-level peak area data allowed for quantitative comparisons in compounds whose precursor ion chromatogram was too noisy for peak integration.


Standard mixture assay is reported in the current study MTBLS1311.

Mouse liver assays are reported in MTBLS1266.

INSTRUMENT(S): Liquid Chromatography MS - positive - hilic

SUBMITTER: guoshou teo 

PROVIDER: MTBLS1311 | MetaboLights | 2021-11-05

REPOSITORIES: MetaboLights

Dataset's files

Source:
Action DRS
MTBLS1311 Other
FILES Other
a_MTBLS1311_LC-MS_positive_hilic_metabolite_profiling.txt Txt
i_Investigation.txt Txt
s_MTBLS1311.txt Txt
Items per page:
1 - 5 of 5
altmetric image

Publications

MetaboKit: a comprehensive data extraction tool for untargeted metabolomics.

Narayanaswamy Pradeep P   Teo Guoshou G   Ow Jin Rong JR   Lau Adam A   Kaldis Philipp P   Tate Stephen S   Choi Hyungwon H  

Molecular omics 20201001 5


We have developed MetaboKit, a comprehensive software package for compound identification and relative quantification in mass spectrometry-based untargeted metabolomics analysis. In data dependent acquisition (DDA) analysis, MetaboKit constructs a customized spectral library with compound identities from reference spectral libraries, adducts, dimers, in-source fragments (ISF), MS/MS fragmentation spectra, and more importantly the retention time information unique to the chromatography system use  ...[more]

Similar Datasets

2021-11-02 | MTBLS1266 | MetaboLights
2018-03-26 | MTBLS417 | MetaboLights
2020-07-13 | MTBLS787 | MetaboLights
2020-07-13 | MTBLS816 | MetaboLights
2021-06-07 | PXD022606 | Pride
2022-10-04 | PXD007656 | Pride
2021-07-26 | PXD025103 | Pride
2021-07-26 | PXD020529 | Pride
2018-11-02 | PXD011574 |
2016-05-09 | PXD000266 | Pride