Ultrasound-induced reorientation for multi-angle optical coherence tomography.


ABSTRACT: Organoid and spheroid technology provide valuable insights into developmental biology and oncology. Optical coherence tomography (OCT) is a label-free technique that has emerged as an excellent tool for monitoring the structure and function of these samples. However, mature organoids are often too opaque for OCT. Access to multi-angle views is highly desirable to overcome this limitation, preferably with non-contact sample handling. To fulfil these requirements, we present an ultrasound-induced reorientation method for multi-angle-OCT, which employs a 3D-printed acoustic trap inserted into an OCT imaging system, to levitate and reorient zebrafish larvae and tumor spheroids in a controlled and reproducible manner. A model-based algorithm was developed for the physically consistent fusion of multi-angle data from a priori unknown angles. We demonstrate enhanced penetration depth in the joint 3D-recovery of reflectivity, attenuation, refractive index, and position registration for zebrafish larvae, creating an enabling tool for future applications in volumetric imaging.

SUBMITTER: Kvale Lovmo M 

PROVIDER: S-EPMC10944478 | biostudies-literature | 2024 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Ultrasound-induced reorientation for multi-angle optical coherence tomography.

Kvåle Løvmo Mia M   Deng Shiyu S   Moser Simon S   Leitgeb Rainer R   Drexler Wolfgang W   Ritsch-Marte Monika M  

Nature communications 20240316 1


Organoid and spheroid technology provide valuable insights into developmental biology and oncology. Optical coherence tomography (OCT) is a label-free technique that has emerged as an excellent tool for monitoring the structure and function of these samples. However, mature organoids are often too opaque for OCT. Access to multi-angle views is highly desirable to overcome this limitation, preferably with non-contact sample handling. To fulfil these requirements, we present an ultrasound-induced  ...[more]

Similar Datasets

| S-EPMC3178313 | biostudies-other
| S-EPMC8361292 | biostudies-literature
| S-EPMC6440039 | biostudies-literature
| S-EPMC6991137 | biostudies-literature
| S-EPMC5116674 | biostudies-literature
| S-EPMC10449890 | biostudies-literature
| S-EPMC8982998 | biostudies-literature
| S-EPMC3684006 | biostudies-literature
| S-EPMC7666918 | biostudies-literature
| S-EPMC9678276 | biostudies-literature