Quantification of Prostate Cancer Metabolism Using 3D Multiecho bSSFP and Hyperpolarized [1-13 C] Pyruvate: Metabolism Differs Between Tumors of the Same Gleason Grade.


ABSTRACT:

Background

Three-dimensional (3D) multiecho balanced steady-state free precession (ME-bSSFP) has previously been demonstrated in preclinical hyperpolarized (HP) 13 C-MRI in vivo experiments, and it may be suitable for clinical metabolic imaging of prostate cancer (PCa).

Purpose

To validate a signal simulation framework for the use of sequence parameter optimization. To demonstrate the feasibility of ME-bSSFP for HP 13 C-MRI in patients. To evaluate the metabolism in PCa measured by ME-bSSFP.

Study type

Retrospective single-center cohort study.

Phantoms/population

Phantoms containing aqueous solutions of [1-13 C] lactate (2.3 M) and [13 C] urea (8 M). Eight patients (mean age 67 ± 6 years) with biopsy-confirmed Gleason 3 + 4 (n = 7) and 4 + 3 (n = 1) PCa. FIELD STRENGTH/SEQUENCES: 1 H MRI at 3 T with T2 -weighted turbo spin-echo sequence used for spatial localization and spoiled dual gradient-echo sequence used for B0 -field measurement. ME-bSSFP sequence for 13 C MR spectroscopic imaging with retrospective multipoint IDEAL metabolite separation.

Assessment

The primary endpoint was the analysis of pyruvate-to-lactate conversion in PCa and healthy prostate regions of interest (ROIs) using model-free area under the curve (AUC) ratios and a one-directional kinetic model (kP ). The secondary objectives were to investigate the correlation between simulated and experimental ME-bSSFP metabolite signals for HP 13 C-MRI parameter optimization.

Statistical tests

Pearson correlation coefficients with 95% confidence intervals and paired t-tests. The level of statistical significance was set at P < 0.05.

Results

Strong correlations between simulated and empirical ME-bSSFP signals were found (r > 0.96). Therefore, the simulation framework was used for sequence optimization. Whole prostate metabolic HP 13 C-MRI, observing the conversion of pyruvate into lactate, with a temporal resolution of 6 seconds was demonstrated using ME-bSSFP. Both assessed metrics resulted in significant differences between PCa (mean ± SD) (AUC = 0.33 ± 012, kP  = 0.038 ± 0.014) and healthy (AUC = 0.15 ± 0.10, kP  = 0.011 ± 0.007) ROIs.

Data conclusion

Metabolic HP 13 C-MRI in the prostate using ME-bSSFP allows for differentiation between aggressive PCa and healthy tissue.

Evidence level

2 TECHNICAL EFFICACY: Stage 1.

SUBMITTER: Chowdhury R 

PROVIDER: S-EPMC10946772 | biostudies-literature | 2023 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications


<h4>Background</h4>Three-dimensional (3D) multiecho balanced steady-state free precession (ME-bSSFP) has previously been demonstrated in preclinical hyperpolarized (HP) <sup>13</sup> C-MRI in vivo experiments, and it may be suitable for clinical metabolic imaging of prostate cancer (PCa).<h4>Purpose</h4>To validate a signal simulation framework for the use of sequence parameter optimization. To demonstrate the feasibility of ME-bSSFP for HP <sup>13</sup> C-MRI in patients. To evaluate the metabo  ...[more]

Similar Datasets

| S-EPMC6008482 | biostudies-literature
| S-EPMC6880930 | biostudies-literature
| S-EPMC5554620 | biostudies-literature
| S-EPMC9231312 | biostudies-literature
| S-EPMC9321735 | biostudies-literature
| S-EPMC6435102 | biostudies-literature
| S-EPMC5432492 | biostudies-literature
| S-EPMC10891046 | biostudies-literature
| S-EPMC10258534 | biostudies-literature
| S-EPMC7927572 | biostudies-literature