Unknown

Dataset Information

0

Variable incidence angle fluorescence interference contrast microscopy for z-imaging single objects.


ABSTRACT: Surface-generated structured illumination microscopies interrogate the position of fluorescently labeled objects near surfaces with nanometer resolution along the z axis. However, these techniques are either experimentally cumbersome or applicable to a limited set of experimental systems. We present a new type of surface-generated structured illumination fluorescence microscopy, variable incidence angle fluorescence interference contrast microscopy (VIA-FLIC), in which the fluorescent sample is assembled above a reflective Si surface and the incidence angle of excitation light is varied by placing annular photomasks with different radii in the aperture diaphragm plane of the microscope. The variation in incidence angle alters the interference pattern of excitation light, and hence the intensity of detected fluorescence. Quantitative VIA-FLIC is tested by using a set of fluorophore-containing supported membranes separated from the Si surface by SiO2 layers of variable thicknesses. The resulting fluorescence intensity versus incidence angle curves depends on the separation from the Si surface and when fit with an appropriate model yield precise SiO2 thicknesses that are accurate with respect to the known SiO2 thicknesses. Since only a simple modification to a standard epifluorescence microscope is required, VIA-FLIC offers a versatile method to produce z-reconstructions with high resolution for a wide range of biological systems.

SUBMITTER: Ajo-Franklin CM 

PROVIDER: S-EPMC1366776 | biostudies-literature | 2005 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Variable incidence angle fluorescence interference contrast microscopy for z-imaging single objects.

Ajo-Franklin Caroline M CM   Ganesan Prasad V PV   Boxer Steven G SG  

Biophysical journal 20050805 4


Surface-generated structured illumination microscopies interrogate the position of fluorescently labeled objects near surfaces with nanometer resolution along the z axis. However, these techniques are either experimentally cumbersome or applicable to a limited set of experimental systems. We present a new type of surface-generated structured illumination fluorescence microscopy, variable incidence angle fluorescence interference contrast microscopy (VIA-FLIC), in which the fluorescent sample is  ...[more]

Similar Datasets

| S-EPMC5034310 | biostudies-literature
| S-EPMC3219692 | biostudies-literature
| S-EPMC3601652 | biostudies-other
| S-EPMC2798991 | biostudies-literature
| S-EPMC4471612 | biostudies-literature
| S-EPMC6240104 | biostudies-literature
| S-EPMC6424346 | biostudies-literature
| S-EPMC8341626 | biostudies-literature
| S-EPMC4260613 | biostudies-literature
| S-EPMC6141597 | biostudies-literature