Unknown

Dataset Information

0

The use of inversion mode and 3D manual segmentation in volume measurement of fetal fluid-filled structures: comparison with Virtual Organ Computer-aided AnaLysis (VOCAL).


ABSTRACT: OBJECTIVE:Volume measurements by three-dimensional (3D) ultrasonography are considered more accurate than those performed by two-dimensional (2D) ultrasonography. The purpose of this study was to compare the agreement of three techniques, as well as the inter- and intraobserver agreements for volume measurements of fetal fluid-filled structures. METHODS:Fifty 3D volume datasets of fetal stomachs and bladders were explored. Volume measurements were performed independently by two observers using: (1) Virtual Organ Computer-aided AnaLysis (VOCAL); (2) inversion mode; and (3) 'manual segmentation'. Reliability was evaluated using intraclass correlation coefficient (ICC), and Bland-Altman plots were generated to examine bias and agreement. The time required to complete the measurements was compared using Student's t-test or the Wilcoxon Signed Rank Test, and P-values < 0.025 or < 0.05 were considered statistically significant. RESULTS:All volume datasets could be measured using the three techniques. A high degree of reliability was observed between: (1) VOCAL and inversion mode (ICC, 0.995; 95% CI, 0.992-0.997); (2) VOCAL and manual segmentation (ICC, 0.997; 95% CI, 0.995-0.998); and (3) inversion mode and manual segmentation (ICC, 0.995; 95% CI, 0.992-0.997). There was good agreement between VOCAL and inversion mode (mean, - 2.4%; 95% limits of agreement, - 20.1 to 15.3%), VOCAL and manual segmentation (mean, - 8.3%; 95% limits of agreement, - 28.8 to 12.2%) as well as between inversion mode and manual segmentation (mean, 5.9%, 95% limits of agreement: - 14.3 to 26%). Manual segmentation and inversion mode measurements were obtained significantly faster than those by VOCAL. CONCLUSIONS:Volume measurements of fetal fluid-filled structures of relatively regular shape with inversion mode and manual segmentation are feasible. Both techniques have good agreement with VOCAL and are significantly faster than VOCAL. Inversion mode is a reliable method for volume calculations of fluid-filled organs, whereas manual segmentation can be used when volume measurements by VOCAL or inversion mode are technically difficult to obtain, such as solid structures with poorly defined borders as the volume dataset is rotated, like the uterine cervix.

SUBMITTER: Kusanovic JP 

PROVIDER: S-EPMC2398614 | biostudies-literature | 2008 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

The use of inversion mode and 3D manual segmentation in volume measurement of fetal fluid-filled structures: comparison with Virtual Organ Computer-aided AnaLysis (VOCAL).

Kusanovic J P JP   Nien J K JK   Gonçalves L F LF   Espinoza J J   Lee W W   Balasubramaniam M M   Soto E E   Erez O O   Romero R R  

Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology 20080201 2


<h4>Objective</h4>Volume measurements by three-dimensional (3D) ultrasonography are considered more accurate than those performed by two-dimensional (2D) ultrasonography. The purpose of this study was to compare the agreement of three techniques, as well as the inter- and intraobserver agreements for volume measurements of fetal fluid-filled structures.<h4>Methods</h4>Fifty 3D volume datasets of fetal stomachs and bladders were explored. Volume measurements were performed independently by two ob  ...[more]

Similar Datasets

| S-EPMC3700613 | biostudies-literature
| S-EPMC3432102 | biostudies-other
| S-EPMC7987253 | biostudies-literature
| S-EPMC4229306 | biostudies-literature
| S-EPMC7294690 | biostudies-literature
| S-EPMC3175283 | biostudies-literature
2021-05-12 | GSE152992 | GEO
| S-EPMC4761951 | biostudies-literature
| S-EPMC5120820 | biostudies-literature
| S-EPMC8094346 | biostudies-literature