Unknown

Dataset Information

0

A robust two-dimensional separation for top-down tandem mass spectrometry of the low-mass proteome.


ABSTRACT: For fractionation of intact proteins by molecular weight (MW), a sharply improved two-dimensional (2D) separation is presented to drive reproducible and robust fractionation before top-down mass spectrometry of complex mixtures. The "GELFrEE" (i.e., gel-eluted liquid fraction entrapment electrophoresis) approach is implemented by use of Tris-glycine and Tris-tricine gel systems applied to human cytosolic and nuclear extracts from HeLa S3 cells, to achieve a MW-based fractionation of proteins from 5 to >100 kDa in 1 h. For top-down tandem mass spectroscopy (MS/MS) of the low-mass proteome (5-25 kDa), between 5 and 8 gel-elution (GE) fractions are sampled by nanocapillary-LC-MS/MS with 12 or 14.5 tesla Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometers. Single injections give about 40 detectable proteins, about half of which yield automated ProSight identifications. Reproducibility metrics of the system are presented, along with comparative analysis of protein targets in mitotic versus asynchronous cells. We forward this basic 2D approach to facilitate wider implementation of top-down mass spectrometry and a variety of other protein separation and/or characterization approaches.

SUBMITTER: Lee JE 

PROVIDER: S-EPMC2830800 | biostudies-literature | 2009 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

A robust two-dimensional separation for top-down tandem mass spectrometry of the low-mass proteome.

Lee Ji Eun JE   Kellie John F JF   Tran John C JC   Tipton Jeremiah D JD   Catherman Adam D AD   Thomas Haylee M HM   Ahlf Dorothy R DR   Durbin Kenneth R KR   Vellaichamy Adaikkalam A   Ntai Ioanna I   Marshall Alan G AG   Kelleher Neil L NL  

Journal of the American Society for Mass Spectrometry 20090812 12


For fractionation of intact proteins by molecular weight (MW), a sharply improved two-dimensional (2D) separation is presented to drive reproducible and robust fractionation before top-down mass spectrometry of complex mixtures. The "GELFrEE" (i.e., gel-eluted liquid fraction entrapment electrophoresis) approach is implemented by use of Tris-glycine and Tris-tricine gel systems applied to human cytosolic and nuclear extracts from HeLa S3 cells, to achieve a MW-based fractionation of proteins fro  ...[more]

Similar Datasets

| S-EPMC3478404 | biostudies-literature
| S-EPMC6060996 | biostudies-literature
| S-EPMC6557293 | biostudies-literature
| S-EPMC3262231 | biostudies-literature
| S-EPMC4238646 | biostudies-literature
| S-EPMC4420533 | biostudies-literature
| S-EPMC3010896 | biostudies-literature
| S-EPMC8564867 | biostudies-literature
| S-EPMC5930140 | biostudies-literature
| S-EPMC8564864 | biostudies-literature