Simultaneous multiple-excitation multiphoton microscopy yields increased imaging sensitivity and specificity.


ABSTRACT:

Background

Multiphoton microscopy (MPM) offers many advantages over conventional wide-field and confocal laser scanning microscopy (CLSM) for imaging biological samples such as 3D resolution of excitation, reduced phototoxicity, and deeper tissue imaging. However, adapting MPM for critical multi-color measurements presents a challenge because of the largely overlapping two-photon absorption (TPA) peaks of common biological fluorophores. Currently, most multi-color MPM relies on the absorbance at one intermediate wavelength of multiple dyes, which introduces problems such as decreased and unequal excitation efficiency across the set of dyes.

Results

Here we describe an MPM system incorporating two, independently controlled sources of two-photon excitation whose wavelengths are adjusted to maximally excite one dye while minimally exciting the other. We report increased signal-to-noise ratios and decreased false positive emission bleed-through using this novel multiple-excitation MPM (ME-MPM) compared to conventional single-excitation MPM (SE-MPM) in a variety of multi-color imaging applications.

Conclusions

Similar to the tremendous gain in popularity of CLSM after the introduction of multi-color imaging, we anticipate that the ME-MPM system will further increase the popularity of MPM. In addition, ME-MPM provides an excellent tool to more rapidly design and optimize pairs of fluorescence probes for multi-color two-photon imaging, such as CFP/YFP or GFP/DsRed for CLSM.

SUBMITTER: Butko MT 

PROVIDER: S-EPMC3062589 | biostudies-literature | 2011 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Simultaneous multiple-excitation multiphoton microscopy yields increased imaging sensitivity and specificity.

Butko Margaret T MT   Drobizhev Mikhail M   Makarov Nikolay S NS   Rebane Aleksander A   Brinkman Brendan C BC   Gleeson Joseph G JG  

BMC biotechnology 20110302


<h4>Background</h4>Multiphoton microscopy (MPM) offers many advantages over conventional wide-field and confocal laser scanning microscopy (CLSM) for imaging biological samples such as 3D resolution of excitation, reduced phototoxicity, and deeper tissue imaging. However, adapting MPM for critical multi-color measurements presents a challenge because of the largely overlapping two-photon absorption (TPA) peaks of common biological fluorophores. Currently, most multi-color MPM relies on the absor  ...[more]

Similar Datasets

| S-EPMC7004891 | biostudies-literature
| S-EPMC3022205 | biostudies-literature
| S-EPMC1159039 | biostudies-literature
| S-EPMC3241964 | biostudies-literature
| S-EPMC4132828 | biostudies-literature
| S-EPMC4914181 | biostudies-literature
| S-EPMC5517475 | biostudies-literature
| S-EPMC6980307 | biostudies-literature
| S-EPMC6458155 | biostudies-literature