Unknown

Dataset Information

0

Desorption electrospray ionization-mass spectrometry of proteins.


ABSTRACT: Desorption electrospray ionization-mass spectrometry (DESI-MS) was evaluated for the detection of proteins ranging in molecular mass from 12 to 66 kDa. Proteins were uniformly deposited on a solid surface without pretreatment and analyzed with a DESI source coupled to a quadrupole ion trap mass spectrometer. DESI-MS parameters optimized for protein detection included solvent flow rate, temperature of heated capillary tube, incident and reflection angle, sheath gas pressure, and ESI voltage. Detection limits were obtained for all protein standards, and they were found to decrease with decreasing protein molecular mass: for cytochrome c (12.3 kDa) and lysozyme (14.3 kDa) a detection limit of 4 ng/mm2 was obtained; for apomyoglobin (16.9 kDa) 20 ng/mm2; for beta-lactoglobulin B (18.2 kDa) 50 ng/mm2; and for chymotrypsinogen A (25.6 kDa) 100 ng/mm2. The DESI-MS analysis of higher molecular mass proteins such as ovalbumin (44.4 kDa) and bovine serum albumin (66.4 kDa) yielded mass spectra of low signal-to-noise ratio, making their detection and molecular weight determination difficult. In this study, DESI-MS proved to be a rapid and robust method for accurate MW determination for proteins up to 17 kDa under ambient conditions. Finally, we demonstrated the DESI-MS detection of the bacteriophage MS2 capsid protein from crude samples with minimal sample preparation.

SUBMITTER: Shin YS 

PROVIDER: S-EPMC3176668 | biostudies-literature | 2007 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Desorption electrospray ionization-mass spectrometry of proteins.

Shin Yong-Seung YS   Drolet Barbara B   Mayer Richard R   Dolence Kurt K   Basile Franco F  

Analytical chemistry 20070330 9


Desorption electrospray ionization-mass spectrometry (DESI-MS) was evaluated for the detection of proteins ranging in molecular mass from 12 to 66 kDa. Proteins were uniformly deposited on a solid surface without pretreatment and analyzed with a DESI source coupled to a quadrupole ion trap mass spectrometer. DESI-MS parameters optimized for protein detection included solvent flow rate, temperature of heated capillary tube, incident and reflection angle, sheath gas pressure, and ESI voltage. Dete  ...[more]

Similar Datasets

| S-EPMC3165113 | biostudies-literature
| S-EPMC6102199 | biostudies-literature
| S-EPMC3259225 | biostudies-literature
| S-EPMC5887808 | biostudies-other
| S-EPMC2587601 | biostudies-literature
| S-EPMC6821845 | biostudies-literature
| S-EPMC5156945 | biostudies-literature
| S-EPMC9013061 | biostudies-literature
| S-EPMC3938891 | biostudies-literature
| S-EPMC3901310 | biostudies-literature