Unknown

Dataset Information

0

Electron counting and beam-induced motion correction enable near-atomic-resolution single-particle cryo-EM.


ABSTRACT: In recent work with large high-symmetry viruses, single-particle electron cryomicroscopy (cryo-EM) has achieved the determination of near-atomic-resolution structures by allowing direct fitting of atomic models into experimental density maps. However, achieving this goal with smaller particles of lower symmetry remains challenging. Using a newly developed single electron-counting detector, we confirmed that electron beam-induced motion substantially degrades resolution, and we showed that the combination of rapid readout and nearly noiseless electron counting allow image blurring to be corrected to subpixel accuracy, restoring intrinsic image information to high resolution (Thon rings visible to ?3 Å). Using this approach, we determined a 3.3-Å-resolution structure of an ?700-kDa protein with D7 symmetry, the Thermoplasma acidophilum 20S proteasome, showing clear side-chain density. Our method greatly enhances image quality and data acquisition efficiency-key bottlenecks in applying near-atomic-resolution cryo-EM to a broad range of protein samples.

SUBMITTER: Li X 

PROVIDER: S-EPMC3684049 | biostudies-literature | 2013 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Electron counting and beam-induced motion correction enable near-atomic-resolution single-particle cryo-EM.

Li Xueming X   Mooney Paul P   Zheng Shawn S   Booth Christopher R CR   Braunfeld Michael B MB   Gubbens Sander S   Agard David A DA   Cheng Yifan Y  

Nature methods 20130505 6


In recent work with large high-symmetry viruses, single-particle electron cryomicroscopy (cryo-EM) has achieved the determination of near-atomic-resolution structures by allowing direct fitting of atomic models into experimental density maps. However, achieving this goal with smaller particles of lower symmetry remains challenging. Using a newly developed single electron-counting detector, we confirmed that electron beam-induced motion substantially degrades resolution, and we showed that the co  ...[more]

Similar Datasets

| S-EPMC7611073 | biostudies-literature
| S-EPMC8009872 | biostudies-literature
| S-EPMC3155204 | biostudies-literature
| S-EPMC3107675 | biostudies-literature
| S-EPMC5373346 | biostudies-literature
| S-EPMC5003279 | biostudies-literature
| S-EPMC4435692 | biostudies-literature
| S-EPMC5385133 | biostudies-literature
| S-EPMC3725109 | biostudies-literature
| S-EPMC4493910 | biostudies-literature