Low-cost microcontroller platform for studying lymphatic biomechanics in vitro.


ABSTRACT: The pumping innate to collecting lymphatic vessels routinely exposes the endothelium to oscillatory wall shear stress and other dynamic forces. However, studying the mechanical sensitivity of the lymphatic endothelium remains a difficult task due to limitations of commercial or custom systems to apply a variety of time-varying stresses in vitro. Current biomechanical in vitro testing devices are very expensive, limited in capability, or highly complex; rendering them largely inaccessible to the endothelial cell biology community. To address these shortcomings, the authors propose a reliable, low-cost platform for augmenting the capabilities of commercially available pumps to produce a wide variety of flow rate waveforms. In particular, the Arduino Uno, a microcontroller development board, is used to provide open-loop control of a digital peristaltic pump using precisely timed serial commands. In addition, the flexibility of this platform is further demonstrated through its support of a custom-built cell-straining device capable of producing oscillatory strains with varying amplitudes and frequencies. Hence, this microcontroller development board is shown to be an inexpensive, precise, and easy-to-use tool for supplementing in vitro assays to quantify the effects of biomechanical forces on lymphatic endothelial cells.

SUBMITTER: Kornuta JA 

PROVIDER: S-EPMC3831339 | biostudies-literature | 2013 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Low-cost microcontroller platform for studying lymphatic biomechanics in vitro.

Kornuta Jeffrey A JA   Nipper Matthew E ME   Dixon J Brandon JB  

Journal of biomechanics 20121121 1


The pumping innate to collecting lymphatic vessels routinely exposes the endothelium to oscillatory wall shear stress and other dynamic forces. However, studying the mechanical sensitivity of the lymphatic endothelium remains a difficult task due to limitations of commercial or custom systems to apply a variety of time-varying stresses in vitro. Current biomechanical in vitro testing devices are very expensive, limited in capability, or highly complex; rendering them largely inaccessible to the  ...[more]

Similar Datasets

| S-EPMC10810312 | biostudies-literature
| S-EPMC10393824 | biostudies-literature
| S-EPMC5780519 | biostudies-literature
| S-EPMC7552646 | biostudies-literature
2017-02-17 | GSE92495 | GEO
| S-EPMC5565099 | biostudies-literature
| S-EPMC9031717 | biostudies-literature
| S-EPMC7506672 | biostudies-literature
| S-EPMC7057232 | biostudies-literature
| S-EPMC6348682 | biostudies-literature