A microfluidic paper-based analytical device for rapid quantification of particulate chromium.


ABSTRACT: Occupational exposure to Cr is concerning because of its myriad of health effects. Assessing chromium exposure is also cost and resource intensive because the analysis typically uses sophisticated instrumental techniques like inductively coupled plasma-mass spectrometry (ICP-MS). Here, we report a novel, simple, inexpensive microfluidic paper-based analytical device (?PAD) for measuring total Cr in airborne particulate matter. In the ?PAD, tetravalent cerium (Ce(IV)) was used in a pretreatment zone to oxidize all soluble Cr to Cr(VI). After elution to the detection zone, Cr(VI) reacts with 1,5-diphenylcarbazide (1,5-DPC) forming 1,5-diphenylcarbazone (DPCO) and Cr(III). The resulting Cr(III) forms a distinct purple colored complex with the DPCO. As proof-of-principle, particulate matter (PM) collected on a sample filter was analyzed with the ?PAD to quantify the mass of total Cr. A log-linear working range (0.23-3.75 ?g; r(2)=0.998) between Cr and color intensity was obtained with a detection limit of 0.12 ?g. For validation, a certified reference containing multiple competing metals was analyzed. Quantitative agreement was obtained between known Cr levels in the sample and the Cr measured using the ?PAD.

SUBMITTER: Rattanarat P 

PROVIDER: S-EPMC3842604 | biostudies-literature | 2013 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

A microfluidic paper-based analytical device for rapid quantification of particulate chromium.

Rattanarat Poomrat P   Dungchai Wijitar W   Cate David M DM   Siangproh Weena W   Volckens John J   Chailapakul Orawon O   Henry Charles S CS  

Analytica chimica acta 20130912


Occupational exposure to Cr is concerning because of its myriad of health effects. Assessing chromium exposure is also cost and resource intensive because the analysis typically uses sophisticated instrumental techniques like inductively coupled plasma-mass spectrometry (ICP-MS). Here, we report a novel, simple, inexpensive microfluidic paper-based analytical device (μPAD) for measuring total Cr in airborne particulate matter. In the μPAD, tetravalent cerium (Ce(IV)) was used in a pretreatment z  ...[more]

Similar Datasets

| S-EPMC3556395 | biostudies-literature
| S-EPMC7071557 | biostudies-literature
| S-EPMC4470859 | biostudies-literature
| S-EPMC5430703 | biostudies-literature
| S-EPMC7435633 | biostudies-literature
| S-EPMC10633824 | biostudies-literature
| S-EPMC8777769 | biostudies-literature
| S-EPMC10857764 | biostudies-literature
| S-EPMC9050516 | biostudies-literature