Quantitative Fluorescence Assays Using a Self-Powered Paper-Based Microfluidic Device and a Camera-Equipped Cellular Phone.


ABSTRACT: Fluorescence assays often require specialized equipment and, therefore, are not easily implemented in resource-limited environments. Herein we describe a point-of-care assay strategy in which fluorescence in the visible region is used as a readout, while a camera-equipped cellular phone is used to capture the fluorescent response and quantify the assay. The fluorescence assay is made possible using a paper-based microfluidic device that contains an internal fluidic battery, a surface-mount LED, a 2-mm section of a clear straw as a cuvette, and an appropriately-designed small molecule reagent that transforms from weakly fluorescent to highly fluorescent when exposed to a specific enzyme biomarker. The resulting visible fluorescence is digitized by photographing the assay region using a camera-equipped cellular phone. The digital images are then quantified using image processing software to provide sensitive as well as quantitative results. In a model 30 min assay, the enzyme ?-D-galactosidase was measured quantitatively down to 700 pM levels. This Communication describes the design of these types of assays in paper-based microfluidic devices and characterizes the key parameters that affect the sensitivity and reproducibility of the technique.

SUBMITTER: Thom NK 

PROVIDER: S-EPMC3904390 | biostudies-literature | 2014 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Quantitative Fluorescence Assays Using a Self-Powered Paper-Based Microfluidic Device and a Camera-Equipped Cellular Phone.

Thom Nicole K NK   Lewis Gregory G GG   Yeung Kimy K   Phillips Scott T ST  

RSC advances 20140101 3


Fluorescence assays often require specialized equipment and, therefore, are not easily implemented in resource-limited environments. Herein we describe a point-of-care assay strategy in which fluorescence in the visible region is used as a readout, while a camera-equipped cellular phone is used to capture the fluorescent response and quantify the assay. The fluorescence assay is made possible using a paper-based microfluidic device that contains an internal fluidic battery, a surface-mount LED,  ...[more]

Similar Datasets

| S-EPMC5628584 | biostudies-literature
| S-EPMC8107377 | biostudies-literature
| S-EPMC3556395 | biostudies-literature
| S-EPMC3651861 | biostudies-other
| S-EPMC7249063 | biostudies-literature
| S-EPMC3842604 | biostudies-literature
| S-EPMC7113244 | biostudies-literature
| S-EPMC7794956 | biostudies-literature
| S-EPMC6974776 | biostudies-literature
| S-EPMC6296866 | biostudies-literature